Evidence map›Paper›PMID 32963748›Full record

ArticleJournal of healthcare engineering2020

Kinematic Calibration of a Parallel 2-UPS/RRR Ankle Rehabilitation Robot.

Mingjie Dong, Yuan Kong, Jianfeng Li, Wenpei Fan

Abstract read
In one paragraph

Article in Journal of healthcare engineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. State of the art in parallel ankle rehabilitation robot: a systematic review.Journal of neuroengineering and rehabilitation · 2021
    Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mingjie DongBeijing Key Laboratory of Advanced Manufacturing Technology, Faculty of Materials and Manufacturing, Beijing University of Technology, No. 100 Pingleiyuan, Chaoyang District, Beijing, China.
Yuan KongBeijing Key Laboratory of Advanced Manufacturing Technology, Faculty of Materials and Manufacturing, Beijing University of Technology, No. 100 Pingleiyuan, Chaoyang District, Beijing, China.
Jianfeng LiBeijing Key Laboratory of Advanced Manufacturing Technology, Faculty of Materials and Manufacturing, Beijing University of Technology, No. 100 Pingleiyuan, Chaoyang District, Beijing, China.ORCID 0000-0002-4338-6420
Wenpei FanBeijing Key Laboratory of Advanced Manufacturing Technology, Faculty of Materials and Manufacturing, Beijing University of Technology, No. 100 Pingleiyuan, Chaoyang District, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In order to better perform rehabilitation training on the ankle joint complex in the direction of dorsiflexion/plantarflexion and inversion/eversion, especially when performing the isokinetic muscle strength exercise, we need to calibrate the kinematic model to improve its control precision. The ankle rehabilitation robot we develop is a parallel mechanism, with its movements in the two directions driven by two linear motors. Inverse solution of positions is deduced and the output lengths of the two UPS kinematic branches are calibrated in the directions of dorsiflexion, plantarflexion, inversion, and eversion, respectively. Motion of each branch in different directions is fitted in high-order form according to experimental data. Variances, standard deviation, and goodness of fit are taken into consideration when choosing the best fitting curve, which ensures that each calibration can match the most appropriate fitting curve. Experiments are conducted to verify the effectiveness of the kinematic calibration after finishing the calibration, and the errors before and after calibration of the two kinematic chains in different directions are compared, respectively, which shows that the accuracy after calibration has been significantly improved.

Indexed as

Range of Motion, ArticularRoboticsAnkleAnkle JointBiomechanical PhenomenaCalibrationFootHumansMotionMovementMuscle, SkeletalMuscle StrengthReproducibility of Results

Identifiers

PMID32963748
PMCPMC7486647

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.