Point-of-care DNA testing by automatically and sequentially performing extraction, amplification and identification in a closed-type cassette.

Tianhui Dong, Xueping Ma, Nan Sheng, Xiemin Qi, Yanan Chu, Qinxin Song, Bingjie Zou, Guohua Zhou

Abstract read
In one paragraph

Article in Sensors and actuators. B, Chemical, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tianhui DongSchool of Life Science and Technology, China Pharmaceutical University, Nanjing 210009, China.
Xueping MaDepartment of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing, 210002, China.
Nan ShengSchool of Life Science and Technology, China Pharmaceutical University, Nanjing 210009, China.
Xiemin QiDepartment of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing, 210002, China.
Yanan ChuDepartment of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing, 210002, China.
Qinxin SongSchool of Life Science and Technology, China Pharmaceutical University, Nanjing 210009, China.
Bingjie ZouDepartment of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing, 210002, China.
Guohua ZhouSchool of Life Science and Technology, China Pharmaceutical University, Nanjing 210009, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Nucleic acid detection is important for clinical diagnostics; however, it is challenging to perform genetic testing at the point-of-care due to the tedious steps involved in DNA extraction and the risk of cross-contamination from amplicons. To achieve a fully-automated and contamination-free nucleic acid detection, we propose a closed-type cassette system which enables the following steps to be operated automatically and sequentially: sample preparation based on magnetic beads, target amplification using multiplex polymerase chain reaction, and colorimetric detection of amplicons using a serial invasive reaction coupled with the aggregation of gold nanoparticle probes. The cassette was designed to be round and closed, and 10 targets in a sample could be simultaneously detected by the naked eye or using a spectrophotometer in the system. In addition, a cassette-driven device was fabricated to transfer reagents between wells, to control the temperature of each reaction, and to sense the colour in the detection wells. The cassette system was sensitive enough to detect 10 genotypes at 5 single nucleotide polymorphism sites related to the anticoagulant's usage, by using a 0.5 μL blood sample. The accuracy of the system was evaluated by detecting 12 whole blood samples, and the results obtained were consistent with those obtained using pyrosequencing. The cassette is airtight and the whole system is fully automatic; the only manual operation is the addition of the sample to the cassette, performing point-of-care genetic testing in a sample-in/answer-out way.

Indexed as

CassetteColorimetric detectionGenetic testMagnetic separationPoint-of-care