Evidence map›Paper›PMID 32960655›Full record

ArticleThe British journal of radiology2020

Prompt gamma imaging for the identification of regional proton range deviations due to anatomic change in a heterogeneous region.

Yunhe Xie, Johannes Petzoldt, Guillaume Janssens, Fionnbarr O'Grady, Lingshu Yin, El Hassane Bentefour, Julien Smeets, Damien Prieels, Robert A Lustig, Alexander Lin and 1 more

Abstract read
In one paragraph

Article in The British journal of radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yunhe XieDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Johannes PetzoldtIon Beam Applications S.A., Louvain-la-Neuve, Belgium.
Guillaume JanssensIon Beam Applications S.A., Louvain-la-Neuve, Belgium.
Fionnbarr O'GradyDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Lingshu YinDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
El Hassane BentefourRadiation Oncology, University of Maryland, Baltimore, MD, USA.
Julien SmeetsIon Beam Applications S.A., Louvain-la-Neuve, Belgium.
Damien PrieelsIon Beam Applications S.A., Louvain-la-Neuve, Belgium.
Robert A LustigDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Alexander LinDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Boon-Keng TeoDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesPrompt gamma (PG) imaging has previously been demonstrated for use in proton range verification of a brain treatment with a homogeneous target region. In this study, the feasibility of PG imaging to detect anatomic change within a heterogeneous region is presented.

methodsA prompt gamma camera recorded several fractions of a patient treatment to the base of skull. An evaluation CT revealed a decrease in sinus cavity filling during the treatment course. Comparison of PG profiles between measurement and simulation was performed to investigate range variations between planned and measured pencil beam spot positions.

resultsFor one field, an average over range of 3 mm due to the anatomic change could be detected for a subset of spots traversing the sinus cavity region. The two other fields appeared less impacted by the change but predicted range variations could not be detected. These results were partially consistent with the simulations of the evaluation CT.

conclusionWe report the first clinical application of PG imaging that detected some of the expected small regional proton range deviations due to anatomic change in a heterogeneous region. However, several limitations exist with the technology that may limit its sensitivity to detect range deviations in heterogeneous regions. ADVANCES IN KNOWLEDGE: We report on the first detection of range variations due to anatomic change in a heterogeneous region using PGI. The results confirm the feasibility of using PG-based range verification in highly heterogeneous target regions to identify deviations from the treatment plan.

Indexed as

Gamma RaysProtonsTomography, X-Ray ComputedBrain NeoplasmsFeasibility StudiesHumansProtons

Identifiers

PMID32960655
PMCPMC7715997

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.