Evidence map›Paper›PMID 32959189›Full record

ArticleClinical rheumatology2021

Reliability of an adapted core strength endurance test battery in individuals with axial spondylarthritis.

Anne-Kathrin Rausch, Philipp Baltisberger, André Meichtry, Beatrice Topalidis, Adrian Ciurea, Theodora P M Vliet Vlieland, Karin Niedermann

Abstract read
In one paragraph

Article in Clinical rheumatology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Anne-Kathrin RauschSchool of Health Professions, Institute of Physiotherapy, Zurich University of Applied Sciences, 8401, Winterthur, Switzerland. rauh@zhaw.ch.ORCID https://orcid.org/0000-0002-7141-4214
Philipp BaltisbergerSchool of Health Professions, Institute of Physiotherapy, Zurich University of Applied Sciences, 8401, Winterthur, Switzerland.
André MeichtrySchool of Health Professions, Institute of Physiotherapy, Zurich University of Applied Sciences, 8401, Winterthur, Switzerland.
Beatrice TopalidisAnkylosing Spondylitis Association of Switzerland, 8050, Zurich, Switzerland.
Adrian CiureaDepartment of Rheumatology, Zurich University Hospital, 8091, Zurich, Switzerland.
Theodora P M Vliet VlielandDepartment of Orthopaedics, Rehabilitation and Physical Therapy, Leiden University Medical Center, Leiden, Netherlands.
Karin NiedermannSchool of Health Professions, Institute of Physiotherapy, Zurich University of Applied Sciences, 8401, Winterthur, Switzerland.

Funding

physioswiss 2017
6 · The paper itself

Abstract

objectivesTo adapt the core strength endurance test battery (aCSE), previously used for testing athletes, to a target group of patients with axial spondylarthritis (axSpA), to evaluate its intra-tester reliability and its associations with disease-specific factors.

methodsA cross-sectional study was conducted at axSpA exercise therapy groups, including both axSpA patients and the physiotherapist group leaders (PTs). The aCSE was used to measure the isometric strength endurance of the ventral, lateral, and dorsal core muscle chains (measured in seconds), as well as to assess the disease-specific factors of functional status, self-reported pain, and perceived strength performance. The aCSE was repeated after 7-14 days to measure intra-tester reliability for the same rater (PT group leader). Reliability was calculated as an intra-class correlation coefficient (ICC) using a nested design. The associations between ventral, lateral, and dorsal strength endurance and the disease-specific factors were calculated using Pearson correlation coefficients.

resultsStudy participants were 13 PT group leaders and 62 axSpA patients. The latter were all capable of performing the aCSE, with the exception of one individual. A moderate to substantial intra-rater reliability (ICCs (95%CI)) was found for the ventral (0.54 (0.35, 0.74)), lateral (0.52 (0.33, 0.70)), and dorsal (0.71 (0.58, 0.86)) core muscle chains. None of the aCSE measures correlated with the disease-specific factors.

conclusionThe aCSE was found to be a reliable test battery for assessing core strength endurance in axSpA patients. Interestingly, aCSE performance was not associated with any disease-specific factors. Key Points • The adapted core strength endurance test battery measures the isometric strength of the ventral, lateral and dorsal core muscle chains. • The adapted core strength endurance test battery showed a moderate to substantial intra-rater reliability for all three muscle chains tested in axSpA patients. • No correlations were found between the adapted core strength endurance test battery and the disease-specific factors of self-reported pain, functional status and perceived strength performance.

Indexed as

Physical EnduranceSpondylarthritisCross-Sectional StudiesExercise TherapyHumansMuscle StrengthReproducibility of ResultsAnkylosing spondylitisAssessmentGroup exercisePhysical therapy

Identifiers

PMID32959189
PMCPMC7943491

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked