Trial reportSurgical endoscopy2021

Comparison of two-dimensional high-definition, ultra high-definition and three-dimensional endovision systems: an ex-vivo randomised study.

Hemanga K Bhattacharjee, Shafneed Chaliyadan, Ashwani K Mishra, Harshit Agarwal, Suhani Suhani, Mohit Joshi, Rajinder Parshad

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Surgical endoscopy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Hemanga K BhattacharjeeDepartment of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India. dr_hkb75@yahoo.com.ORCID 0000-0002-1002-7077
Shafneed ChaliyadanDepartment of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
Ashwani K MishraNational Drug Dependence Treatment Centre (NDDTC), All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
Harshit AgarwalDepartment of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
Suhani SuhaniDepartment of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
Mohit JoshiDepartment of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
Rajinder ParshadDepartment of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
All India Institute of Medical Sciences · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTwo-dimensional high-definition (2D HD) endovision system is preferred for laparoscopic surgery. Recently, new generation three-dimensional (3D) HD and ultra-HD (4K) endovision systems are introduced to improve the safety and efficacy of laparoscopic surgery. There is limited evidence on superiority of one technology over the others. This experimental trial was designed to evaluate 2D HD, 3D HD and 4K HD endovision systems in performance of standardized tasks.

methodsThis was a randomized, cross-over experimental study. Twenty-one surgical residents who were exposed to laparoscopic surgery were enrolled. Participants were randomly assigned into three groups. Each group performed standardised tasks i.e. peg transfer, precision cutting, navigating in space and intra-corporeal suturing using 2D HD, 4K HD and 3D HD endovision systems on a box trainer. Procedures were recorded as 2D HD videos and analysed later. Participant's perceived workload was assessed using Surg-TLX questionnaire. Primary endpoints were execution time in seconds and error score. Secondary endpoint was workload assessment.

resultsThe 3D HD had shorter execution time compared to 2D HD and 4K HD in all tasks except precision cutting (p = 0.004, 0.03, 0.001, 0.001 and p = 0.002, 0.191, 0.006, 0.005 in peg transfer, precision cutting, navigating in space and intra-corporeal suturing respectively). The 4K HD was significantly faster than 2D HD only in navigating in space task (p = 0.002). The error score between 3D HD and 4K HD were comparable in all tasks. The 2D HD had significantly more error scores compared to 4K HD, 3D HD in peg transfer task (p = 0.005, 0.014, respectively). 3D HD had significantly less workload than 2D HD and 4K HD in most of the dimensions of Surg-TLX

conclusions3D HD endovision system in comparison to 2D HD and 4K HD, may lead to faster execution without compromising safety of a task and is associated with less workload.

Indexed as

LaparoscopyClinical CompetenceCross-Over StudiesHumansImaging, Three-DimensionalNeurosurgical ProceduresWorkload2D HD3D HD4K HDEndovision systemLaparoscopySurg-TLX

Identifiers

PMID32959182
OpenAlexW3087277802

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.