Evidence map›Paper›PMID 32959178›Full record

SynthesisJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2021

Radiofrequency atrial fibrillation ablation with irrigated tip catheter using remote magnetic navigation compared with conventional manual method.

Rugheed Ghadban, Kristina Gifft, Zachary Luebbering, Sandeep Sodhi, Daniel Cooper, Tariq Enezate

Abstract readMeta-Analysis
PubMed Publisher
In one paragraph

Synthesis in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Optimal power settings have major impact on procedural efficiency in pulmonary vein isolation guided by robotic magnetic navigation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Rugheed GhadbanDivision of Cardiology, Washington University, St Louis, MO, USA.
Kristina GifftDepartment of General Medicine, University of Missouri Health Care, Columbia, MO, USA.
Zachary LuebberingDivision of Cardiovascular Medicine, University of Missouri Health Care, Columbia, MO, USA.
Sandeep SodhiDivision of Cardiology, Washington University, St Louis, MO, USA.
Daniel CooperDivision of Cardiology, Washington University, St Louis, MO, USA.
Tariq EnezateDivision of Cardiology, University of California Log Angeles-Harbor Medical Center, 1000 W Carson St., Torrance, CA, 90502, USA. tariqenezate@gmail.com.ORCID http://orcid.org/0000-0002-6812-8161
Washington University in St. Louis · USUniversity of Missouri Health System · USUCLA Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundStudies comparing manual catheter navigation (MCN) to remote magnetic navigation (RMN) for atrial fibrillation (AF) ablation showed variable results.

objectiveThe aim of this meta-analysis is to compare the safety and clinical outcomes of AF radiofrequency (RF) ablation using MCN versus RMN with irrigated tip catheters.

methodsMedline and the Cochrane Central Register of Controlled Trials (CENTRAL) were queried from inception through January 2019. Studies comparing safety and clinical outcomes of AF ablation with RF using MCN versus RMN with irrigated tip catheters were included. Random effects meta-analysis was used to pool outcomes across studies. Study endpoints included freedom of AF at the end of the study, procedure total time, fluoroscopy time, and complications.

resultsA total of 14 studies (3 controlled non-randomized trials, 1 prospective observational, and 10 retrospective observational studies) involving 3375 patients (1871 in MCN and 1504 in RMN) were included in this meta-analysis. There was no significant difference between the two groups in terms of freedom of AF (OR 1.08, 95% CI 0.82-1.42, p = 0.52). The MCN group was associated with shorter procedure time (mean difference in minutes - 50.39, 95% CI - 67.99 to - 32.79, p < 0.01), longer fluoroscopy time (mean difference in minutes 18.01, 95% CI 10.73-25.29, p < 0.01), and higher complication rate (OR 2.18, 95% CI 1.24-3.82, p < 0.01).

conclusionsAF ablation utilizing MCN was associated with similar efficacy to RMN but with higher complication rates. Although the procedure time was shorter with MCN, the fluoroscopy time was more prolonged. Randomized clinical studies are needed to further verify these results.

Indexed as

Atrial FibrillationCatheter AblationCathetersHumansMagnetic PhenomenaTreatment OutcomeAblationAnd outcomesAtrial fibrillationManual catheter navigationRemote magnetic navigation

Identifiers

PMID32959178
OpenAlexW3087386641

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.