Evidence map›Paper›PMID 32959159›Full record

ArticleInternational journal of computer assisted radiology and surgery2020

Force quantification and simulation of pedicle screw tract palpation using direct visuo-haptic volume rendering.

Esther I Zoller, Balázs Faludi, Nicolas Gerig, Gregory F Jost, Philippe C Cattin, Georg Rauter

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Automatic patient positioning based on robot rotational workspace for extended reality.International journal of computer assisted radiology and surgery · 2023
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Esther I Zoller *BIROMED-Lab, Department of Biomedical Engineering, University of Basel, Basel, Switzerland. esther.zoller@unibas.ch.ORCID http://orcid.org/0000-0003-3919-145X
Balázs Faludi *CIAN, Department of Biomedical Engineering, University of Basel, Basel, Switzerland.
Nicolas GerigBIROMED-Lab, Department of Biomedical Engineering, University of Basel, Basel, Switzerland.
Gregory F JostSpinale Chirurgie, Spitalzentrum Biel, Biel, Switzerland.
Philippe C CattinCIAN, Department of Biomedical Engineering, University of Basel, Basel, Switzerland.
Georg RauterBIROMED-Lab, Department of Biomedical Engineering, University of Basel, Basel, Switzerland.
University of Basel · CHSpitalzentrum Centre hospitalier Biel- Bienne · CH

Funding

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung 316030_133802Werner Siemens-Stiftung MIRACLE
6 · The paper itself

Abstract

purposeWe present a feasibility study for the visuo-haptic simulation of pedicle screw tract palpation in virtual reality, using an approach that requires no manual processing or segmentation of the volumetric medical data set.

methodsIn a first experiment, we quantified the forces and torques present during the palpation of a pedicle screw tract in a real boar vertebra. We equipped a ball-tipped pedicle probe with a 6-axis force/torque sensor and a motion capture marker cluster. We simultaneously recorded the pose of the probe relative to the vertebra and measured the generated forces and torques during palpation. This allowed us replaying the recorded palpation movements in our simulator and to fine-tune the haptic rendering to approximate the measured forces and torques. In a second experiment, we asked two neurosurgeons to palpate a virtual version of the same vertebra in our simulator, while we logged the forces and torques sent to the haptic device.

resultsIn the experiments with the real vertebra, the maximum measured force along the longitudinal axis of the probe was 7.78 N and the maximum measured bending torque was 0.13 Nm. In an offline simulation of the motion of the pedicle probe recorded during the palpation of a real pedicle screw tract, our approach generated forces and torques that were similar in magnitude and progression to the measured ones. When surgeons tested our simulator, the distributions of the computed forces and torques were similar to the measured ones; however, higher forces and torques occurred more frequently.

conclusionsWe demonstrated the suitability of direct visual and haptic volume rendering to simulate a specific surgical procedure. Our approach of fine-tuning the simulation by measuring the forces and torques that are prevalent while palpating a real vertebra produced promising results.

Indexed as

Computer SimulationPedicle ScrewsVirtual RealityAnimalsFeasibility StudiesMaleMotionPalpationSimulation TrainingSpinal FusionSwineTorqueUser-Computer InterfaceCTHaptic renderingHuman robot interactionMedical simulationVirtual reality

Identifiers

PMID32959159
PMCPMC7603448
OpenAlexW3087148631

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.