Evidence map›Paper›PMID 32957576›Full record

ArticleMaterials (Basel, Switzerland)2020

Degradation Performance of Open-Cell Biomaterials from Phosphated Carbonyl Iron Powder with PEG Coating.

Renáta Oriňaková, Radka Gorejová, Martina Petráková, Zuzana Orságová Králová, Andrej Oriňak, Miriam Kupková, Monika Hrubovčáková, Mária Podobová, Matej Baláž, Roger M Smith

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Renáta OriňakováDepartment of Physical Chemistry, Faculty of Science, Pavol Jozef Šafárik University in Košice, Moyzesova 11, 041-54 Košice, Slovakia.ORCID 0000-0001-8103-2634
Radka GorejováDepartment of Physical Chemistry, Faculty of Science, Pavol Jozef Šafárik University in Košice, Moyzesova 11, 041-54 Košice, Slovakia.ORCID 0000-0002-7892-7581
Martina PetrákováDepartment of Physical Chemistry, Faculty of Science, Pavol Jozef Šafárik University in Košice, Moyzesova 11, 041-54 Košice, Slovakia.
Zuzana Orságová KrálováDepartment of Physical Chemistry, Faculty of Science, Pavol Jozef Šafárik University in Košice, Moyzesova 11, 041-54 Košice, Slovakia.ORCID 0000-0001-8703-0015
Andrej OriňakDepartment of Physical Chemistry, Faculty of Science, Pavol Jozef Šafárik University in Košice, Moyzesova 11, 041-54 Košice, Slovakia.
Miriam KupkováInstitute of Materials Research, Slovak Academy of Sciences, Watsonova 47, 040-01 Košice, Slovakia.
Monika HrubovčákováInstitute of Materials Research, Slovak Academy of Sciences, Watsonova 47, 040-01 Košice, Slovakia.ORCID 0000-0002-0437-9279
Mária PodobováInstitute of Materials Research, Slovak Academy of Sciences, Watsonova 47, 040-01 Košice, Slovakia.
Matej BalážInstitute of Geotechnics, Slovak Academy of Sciences, Watsonova 45, 040-01 Košice, Slovakia.ORCID 0000-0001-6563-7588
Roger M SmithDepartment of Chemistry, Loughborough University, Loughborough, LE11-3TU Leicestershire, UK.ORCID 0000-0002-5252-9649

Funding

Agentúra na Podporu Výskumu a Vývoja APVV-16-0029Agentúra na Podporu Výskumu a Vývoja APVV-18-0357Internal Research Grant System of Faculty of Science of Pavol Jozef Šafárik University in Košice VVGS- pf-2019-1049Vedecká Grantová Agentúra MŠVVaŠ SR a SAV VEGA 1/0074/17Vedecká Grantová Agentúra MŠVVaŠ SR a SAV VEGA 2/0044/18
6 · The paper itself

Abstract

Advances in biomedicine and development of modern technologies in the last century have fostered the improvement in human longevity and well-being. This progress simultaneously initiated the need for novel biomaterials. Recently, degradable metallic biomaterials have attracted serious attention in scientific and clinical research owing to their utilization in some specific applications. This work investigates the effect of the polyethylene glycol (PEG) coating of open-cell iron and phosphorus/iron foams on their microstructure and corrosion properties. The addition of phosphorus causes a slight increase in pore size and the deposition of a polymer coating results in a smoothened surface and a moderate decrease in pore diameter. The PEG coating leads to an increase in corrosion rates in both foams and potentially a more desirable product.

Indexed as

corrosion behaviordegradable biomaterialsironmicrostructurephosphated iron

Identifiers