Evidence map›Paper›PMID 32955698›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2021

Surgical comfort and clinical outcomes of MIPO with an extra-short plate designed for distal radius fractures.

Ghada Asmar, Jonathan Bellity, Marc-Olivier Falcone

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Ghada AsmarRamsay Générale de Santé - Capio - Hôpital Privé Paul d'Egine, 4 avenue Marx Dormoy, 94500, Champigny-Sur-Marne, France.ORCID http://orcid.org/0000-0002-1238-3833
Jonathan BellityRamsay Générale de Santé - Capio - Hôpital Privé Paul d'Egine, 4 avenue Marx Dormoy, 94500, Champigny-Sur-Marne, France.ORCID http://orcid.org/0000-0001-8576-7929
Marc-Olivier FalconeRamsay Générale de Santé - Capio - Hôpital Privé Paul d'Egine, 4 avenue Marx Dormoy, 94500, Champigny-Sur-Marne, France. falcone.research@gmail.com.ORCID http://orcid.org/0000-0003-0609-9550
Générale de Santé · FRInternational Office for Water · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesVolar locking plates (VLPs) are increasingly used for distal radius fractures (DRFs) with minimally invasive plate osteosynthesis (MIPO), but surgery learning curves could be long. The purpose of this study was to assess a new extra-short plate with two locking diaphyseal divergent screws, specifically designed for MIPO, preserving the pronator quadratus muscle. MATERIALS AND

methodsThis retrospective study consisted of three phases: (i) the evaluation of surgical comfort with the incision size and the duration of 59 consecutive surgeries using the extra-short plate in DRFs; (ii) the verification of the implant ability to maintain radiographic indices compared immediately postoperatively and at consolidation. They included radial inclination (RI), volar tilt (VT) and ulnar variance (UV); (iii) the assessment of clinical outcomes at last follow-up through: pain measured on the visual analogue scale (VAS), QuickDASH score, patient-rated wrist evaluation (PRWE) score, grip strength, range of motion and complications.

resultsIn the first phase: mean incision size was 32 mm, and mean operative time was 28.5 min. In the second phase, there was no statistical difference between the two measures of the indices studied. In the third phase, mean follow-up time was 14.2 months, VAS score was 1.1, QuickDASH score was 11.4/100, and PRWE score was 9.5/100. Flexion was 91%, extension was 94%, and grip strength was 86% compared to the contralateral side.

conclusionThe surgical comfort may be related to short operative time and incision. The implant allowed maintaining the radiographic indices without secondary displacement. Functional clinical outcomes were satisfactory. This extra-short plate design belongs to a novel generation of VLPs.

Indexed as

Radius FracturesBone PlatesFracture Fixation, InternalHumansRange of Motion, ArticularRetrospective StudiesTreatment OutcomeWrist JointClinical outcomesDistal radiusExtra-short locking plateFractureMini-invasive approachPronator quadratus

Identifiers

PMID32955698
OpenAlexW3087643522

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.