ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2021
Surgical comfort and clinical outcomes of MIPO with an extra-short plate designed for distal radius fractures.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Minimally invasive plate osteosynthesis for distal radius fractures using a 3-point positioning technique.World journal of orthopedics · 2025Article
- The Outcome of under 10 mm Single-Incision Surgery Using a Non-Specialized Volar Plate in Distal Radius Fractures: A Retrospective Comparative Study.Journal of clinical medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesVolar locking plates (VLPs) are increasingly used for distal radius fractures (DRFs) with minimally invasive plate osteosynthesis (MIPO), but surgery learning curves could be long. The purpose of this study was to assess a new extra-short plate with two locking diaphyseal divergent screws, specifically designed for MIPO, preserving the pronator quadratus muscle. MATERIALS AND
methodsThis retrospective study consisted of three phases: (i) the evaluation of surgical comfort with the incision size and the duration of 59 consecutive surgeries using the extra-short plate in DRFs; (ii) the verification of the implant ability to maintain radiographic indices compared immediately postoperatively and at consolidation. They included radial inclination (RI), volar tilt (VT) and ulnar variance (UV); (iii) the assessment of clinical outcomes at last follow-up through: pain measured on the visual analogue scale (VAS), QuickDASH score, patient-rated wrist evaluation (PRWE) score, grip strength, range of motion and complications.
resultsIn the first phase: mean incision size was 32 mm, and mean operative time was 28.5 min. In the second phase, there was no statistical difference between the two measures of the indices studied. In the third phase, mean follow-up time was 14.2 months, VAS score was 1.1, QuickDASH score was 11.4/100, and PRWE score was 9.5/100. Flexion was 91%, extension was 94%, and grip strength was 86% compared to the contralateral side.
conclusionThe surgical comfort may be related to short operative time and incision. The implant allowed maintaining the radiographic indices without secondary displacement. Functional clinical outcomes were satisfactory. This extra-short plate design belongs to a novel generation of VLPs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.