Evidence map›Paper›PMID 32951603›Full record

ArticleMilitary Medical Research2020

Creation of an optic nerve sheath diameter ultrasound model for NeuroICU education.

Heidi M Felix, Kristin A Rosenbush, Amy M Lannen, Robert A Pooley, Jason L Siegel, Benjamin L Brown, Melissa L McMullan, Christina I Collins, William D Freeman

Open access · diamondAbstract read
In one paragraph

Article in Military Medical Research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Heidi M FelixJ. Wayne and Delores Barr Weaver Simulation Center, Mayo Clinic, 4500 San Pablo Road, Jacksonville, FL, 32224, USA. Felix.Heidi@mayo.edu.
Kristin A RosenbushJ. Wayne and Delores Barr Weaver Simulation Center, Mayo Clinic, 4500 San Pablo Road, Jacksonville, FL, 32224, USA.
Amy M LannenJ. Wayne and Delores Barr Weaver Simulation Center, Mayo Clinic, 4500 San Pablo Road, Jacksonville, FL, 32224, USA.
Robert A PooleyDivision of Medical Physics, Mayo Clinic, Jacksonville, FL, 32224, USA.
Jason L SiegelDepartment of Critical Care Medicine, Mayo Clinic, Jacksonville, FL, 32224, USA.
Benjamin L BrownDepartment of Neurologic Surgery, Mayo Clinic, Jacksonville, FL, 32224, USA.
Melissa L McMullanDepartment of Nursing, Mayo Clinic, Jacksonville, FL, 32224, USA.
Christina I CollinsDepartment of Neurologic Surgery, Mayo Clinic, Jacksonville, FL, 32224, USA.
William D FreemanDepartment of Critical Care Medicine, Mayo Clinic, Jacksonville, FL, 32224, USA.
Jacksonville College · USMayo Clinic in Florida · USWinnMed · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUsing ultrasound to measure optic nerve sheath diameter (ONSD) is an emerging bedside technique to noninvasively assess intracranial pressure (ICP) in patients with brain injury. This technique is unique among bedside ultrasonography and is often performed by providers who have no formal ultrasound training. We sought to create a low-cost, 3D, reusable ONSD model to train neurology, neurosurgery, and critical care providers in measuring ICP.

resultsWe identified 253 articles, of which 15 were associated with models and 2 with simulation. One gelatin model was reported, upon which we based our initial design. We could not validate the visual findings of this model; however, after constructing multiple beta models, the design most representative of human eye anatomy was a globe made of ballistics gel and either a 3 mm, 5 mm, or 7 mm × 50 mm 3D-printed optic nerve inserted into a platform composed of ballistics gel, all of which sat inside a 3D-printed skull. This model was used to teach ONSD measurements with ultrasound at a continuing medical education event prior to training on a live human model.

conclusionA simple 3D ballistic ONSD model allows learners to practice proper hand placement and pressure, basic landmarks, and ONSD measurement prior to operating on a human eye. This model is replicable and sustainable given that the globe and platform are composed of ballistics gel.

Indexed as

Models, AnatomicHumansIntracranial HypertensionIntracranial PressureOptic NervePoint-of-Care SystemsUltrasonographyWeights and MeasuresIntracranial pressureSimulationTask trainerUltrasound

Identifiers

PMID32951603
PMCPMC7504623
OpenAlexW3087668519

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked