Evidence map›Paper›PMID 32942697›Full record

ArticleJournal of clinical medicine2020

Evaluation of Insertion Energy as Novel Parameter for Dental Implant Stability.

Tanja Grobecker-Karl, Anthony Dickinson, Siegfried Heckmann, Matthias Karl, Constanze Steiner

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tanja Grobecker-KarlDepartment of Prosthodontics, Saarland University, Kirrberger Strasse 100, 66421 Homburg, Germany.
Anthony DickinsonPrivate Prosthodontic Practice, 1564 Malvern Road, Glen Iris 3146, Australia.
Siegfried HeckmannDepartment of Prosthodontics, Saarland University, Kirrberger Strasse 100, 66421 Homburg, Germany.
Matthias KarlDepartment of Prosthodontics, Saarland University, Kirrberger Strasse 100, 66421 Homburg, Germany.ORCID 0000-0002-8748-1024
Constanze SteinerDepartment of Prosthodontics, Saarland University, Kirrberger Strasse 100, 66421 Homburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Insertion energy has been advocated as a novel measure for primary implant stability, but the effect of implant length, diameter, or surgical protocol remains unclear. Twenty implants from one specific bone level implant system were placed in layered polyurethane foam measuring maximum insertion torque, torque-time curves, and primary stability using resonance frequency analysis (RFA). Insertion energy was calculated as area under torque-time curve applying the trapezoidal formula. Statistical analysis was based on analysis of variance, Tukey honest differences tests and Pearson's product moment correlation tests (α = 0.05). Implant stability (

Indexed as

insertion energyinsertion torqueprimary implant stabilityresonance frequency analysissurgical protocol

Identifiers

PMID32942697
PMCPMC7565125

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked