ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2021
Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Cementless versus cemented unicompartmental knee arthroplasty: a systematic review of comparative studies.Musculoskeletal surgery · 2023Pooled it
- Computational Study of Stress Distribution in Polyethylene Elements Due to Metal Components of Knee and Hip Implants Made from Different Metal Alloys.Materials (Basel, Switzerland) · 2025Article
- Biomechanical finite element analysis of various tibial plateau posterior tilt angles in medial unicondylar knee arthroplasty.Experimental and therapeutic medicine · 2024Article
- [Current Trends in the Implantation of the Touch Prosthesis at the Thumb Carpometacarpal Joint: Results of the 1st German-Speaking User Meeting].Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V... · 2024Article
- How to Perform Better on Oxford UKA? A Technical Note from over 500 Surgical Experiences.Orthopaedic surgery · 2023Article
- Debridement, Antibiotics, and Implant Retention for an Early Periprosthetic Infection After Unicompartmental Knee Arthroplasty: A Technical Note.Arthroplasty today · 2022Article
- Lateral osteoarthritis progression is associated with a postoperative residual tibiofemoral subluxation in Oxford UKA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Article
- The Oxford Domed Lateral Unicompartmental Knee Replacement implant: Increasing wall height reduces the risk of bearing dislocation.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe Oxford unicompartmental knee replacement (UKR) has a fully congruent mobile bearing to minimise wear. However, with younger higher demand patients, wear remains a concern. The aim of this study was to quantify the wear rate of Phase 3 Oxford UKR bearings over the course of 5 years and to identify the factors that influence it.
methods40 medial Oxford UKRs recruited for a randomised study of cemented and cementless fixation were studied with Radiostereometric analysis (RSA) at 1 week, 3 months, 6 months, 1 year, 2 years, and 5 years post-operatively and bearing thickness was calculated. Penetration, defined as the change in thickness compared to the 1-week measurement, was determined. Creep (early penetration) and wear (late penetration at a constant rate) were calculated. The influence of demographic factors, Oxford Knee Score (OKS), Tegner score, fixation and bearing overhang (determined by RSA) on wear was analysed.
resultsAfter 6 months the penetration rate was constant, indicating that wear alone was occurring. The wear rate was 0.07 mm/year (SD 0.03). The creep was 0.06 mm with about 95% occurring during the first 3 months. There was no significant relationship between fixation (cemented/cementless), age, component size, OKS and Tegner score with wear rate. Increasing BMI was associated with decreasing wear (p = 0.042). 37/40 bearings overhung the tibia to some extent and 23/40 overhung the tibia medially. An increase in the area of overhang (p = 0.036), amount of medial overhang (p = 0.028) and distance between the bearing and tibial wall (p = 0.019) were associated with increased wear. Bearings that did not overhang (0.06 mm/year) had less wear (p = 0.025) than those that did (0.08 mm/year). There was no relationship (p = 0.6) between the femoral contact area and wear.
conclusionDuring the first three to six months after implantation, the bearing becomes 0.06 mm thinner due to creep. The combined wear rate of the upper and lower surfaces of the bearing is constant (0.07 mm/year). The wear is lower if the bearing does not overhang the tibia so surgeons should aim for the bearing to be close to the tibial wall. The orientation of the femoral component does not influence wear. LEVEL OF EVIDENCE: Retrospective Study, Level III.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.