ArticleScientific reports2020
Low-cost portable microwave sensor for non-invasive monitoring of blood glucose level: novel design utilizing a four-cell CSRR hexagonal configuration.
Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 55 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
55 citing papers in PubMed, 254 citations in OpenAlex.
- High-Sensitivity Non-Invasive Microwave Glucose Sensor with ZnO/CNT Composite Optimized by Deep Learning for Wearable Medical Devices.ACS omega · 2026Article
- Non-Invasive Technologies in Wearable Glucose Monitoring: A Structured Overview for the Future.Biosensors · 2026Review
- A Modified Single Metamaterial Split-Ring Resonator for Enhanced Sensitivity.Sensors (Basel, Switzerland) · 2026Article
- A DFT-based Raman spectral atlas and vibrational assignment of aqueous glucose structures and derivatives.Communications chemistry · 2026Article
- Non-enzymatic sweat sensors for pediatric continuous glucose monitoring: a systematic review of engineering readiness and the cost-accuracy trade-off.BMC biomedical engineering · 2026Article
- Design of a microwave sensor for non-invasive monitoring of blood glucose level with high sensitivity using electromagnetic properties.Scientific reports · 2026Article
- A novel AI-enhanced microwave sensor employing defected ground structure for non-invasive glucose monitoring.Scientific reports · 2026Article
- Band-Pass Raman Spectroscopy Unlocks Compact Point-of-Care Noninvasive Continuous Glucose Monitoring.Analytical chemistry · 2025Article
- Sensitivity Evaluation of a Dual-Finger Metamaterial Biosensor for Non-Invasive Glycemia Tracking on Multiple Substrates.Sensors (Basel, Switzerland) · 2025Article
- State-of-the-art wearable sensors for cardiovascular health: a review.NPJ cardiovascular health · 2025Review
- Non-contact measurement of glucose in urine by smartphone-based laser refractometry for diabetes monitoring.Scientific reports · 2025Article
- Near-Field Microwave Sensing for Chip-Level Tamper Detection.Sensors (Basel, Switzerland) · 2025Article
- Microfluidic Microwave Sensor Based on a Twisted Cross-Shaped Structure for Glucose Detection.Sensors (Basel, Switzerland) · 2025Article
- Revolutionizing Diabetes Management Through Nanotechnology-Driven Smart Systems.Pharmaceutics · 2025Review
- Breaking the Specificity Barrier in Microwave Sensing: Highly Specific Lactate Microwave Biosensor for Fitness and Exercise Optimization.ACS sensors · 2025Article
- Transforming Healthcare: Intelligent Wearable Sensors Empowered by Smart Materials and Artificial Intelligence.Advanced materials (Deerfield Beach, Fla.) · 2025Review
- Early Detection of Alzheimer's Disease via Machine Learning-Based Microwave Sensing: An Experimental Validation.Sensors (Basel, Switzerland) · 2025Article
- Improved Fully 3D-Printed SIW-Based Sensor for Non-Invasive Glucose Measurement.Sensors (Basel, Switzerland) · 2025Article
- Quad-band split ring resonator-based sensor for microwave sensing application.Scientific reports · 2025Article
- A Discussion on Sensitivity Optimization in Reflective-Mode Phase-Variation Permittivity Sensors Based on Semi-Lumped Resonators.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This article presents a novel design of portable planar microwave sensor for fast, accurate, and non-invasive monitoring of the blood glucose level as an effective technique for diabetes control and prevention. The proposed sensor design incorporates four cells of hexagonal-shaped complementary split ring resonators (CSRRs), arranged in a honey-cell configuration, and fabricated on a thin sheet of an FR4 dielectric substrate.The CSRR sensing elements are coupled via a planar microstrip-line to a radar board operating in the ISM band 2.4-2.5 GHz. The integrated sensor shows an impressive detection capability and a remarkable sensitivity of blood glucose levels (BGLs). The superior detection capability is attributed to the enhanced design of the CSRR sensing elements that expose the glucose samples to an intense interaction with the electromagnetic fields highly concentrated around the sensing region at the induced resonances. This feature enables the developed sensor to detect extremely delicate variations in the electromagnetic properties that characterize the varying-level glucose samples. The desired performance of the fabricated sensor is practically validated through in-vitro measurements using a convenient setup of Vector Network Analyzer (VNA) that records notable traces of frequency-shift responses when the sensor is loaded with samples of 70-120 mg/dL glucose concentrations. This is also demonstrated in the radar-driven prototype where the raw data collected at the radar receiving channel shows obvious patterns that reflect glucose-level variations. Furthermore, the differences in the sensor responses for tested glucose samples are quantified by applying the Principal Component Analysis (PCA) machine learning algorithm. The proposed sensor, beside its impressive detection capability of the diabetes-spectrum glucose levels, has several other favorable attributes including compact size, simple fabrication, affordable cost, non-ionizing nature, and minimum health risk or impact. Such attractive features promote the proposed sensor as a possible candidate for non-invasive glucose levels monitoring for diabetes as evidenced by the preliminary results from a proof-of-concept in-vivo experiment of tracking an individual's BGL by placing his fingertip onto the sensor. The presented system is a developmental platform towards radar-driven wearable continuous BGL monitors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials