Evidence map›Paper›PMID 32937770›Full record

ArticleSensors (Basel, Switzerland)2020

Simple Wireless Impedance Pneumography System for Unobtrusive Sensing of Respiration.

Pablo Aqueveque, Britam Gómez, Emyrna Monsalve, Enrique Germany, Paulina Ortega-Bastidas, Sebastián Dubo, Esteban J Pino

Open access · goldAbstract readLetter
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 29 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Feasibility Analysis of a Portable Diaphragmatic Efficiency Monitor for CSCI Patients.IEEE journal of translational engineering in health and medicine · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Wearable Sensors for Respiration Monitoring: A Review.Sensors (Basel, Switzerland) · 2023
    Review
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Pablo AquevequeElectrical Engineering Department, Faculty of Engineering, Universidad de Concepción, Edmundo Larenas 219, Concepción 4070409, Chile.ORCID 0000-0001-9101-0383
Britam GómezElectrical Engineering Department, Faculty of Engineering, Universidad de Concepción, Edmundo Larenas 219, Concepción 4070409, Chile.ORCID 0000-0001-6563-2955
Emyrna MonsalveElectrical Engineering Department, Faculty of Engineering, Universidad de Concepción, Edmundo Larenas 219, Concepción 4070409, Chile.
Enrique GermanyElectrical Engineering Department, Faculty of Engineering, Universidad de Concepción, Edmundo Larenas 219, Concepción 4070409, Chile.ORCID 0000-0002-3100-187X
Paulina Ortega-BastidasKinesiology Department, Faculty of Medicine, Universidad de Concepción, Chacabuco 1401, Concepción 4070409, Chile.ORCID 0000-0002-9333-3036
Sebastián DuboKinesiology Department, Faculty of Medicine, Universidad de Concepción, Chacabuco 1401, Concepción 4070409, Chile.ORCID 0000-0002-3206-0433
Esteban J PinoElectrical Engineering Department, Faculty of Engineering, Universidad de Concepción, Edmundo Larenas 219, Concepción 4070409, Chile.ORCID 0000-0002-2636-051X
University of Concepción · CL

Funding

CONICYT FONDECYT Regular Folio 1201543
6 · The paper itself

Abstract

This extended paper presents the development and implementation at a prototype level of a wireless, low-cost system for the measurement of the electrical bioimpedance of the chest with two channels using the AD5933 in a bipolar electrode configuration to measure impedance pneumography. The measurement device works for impedance measurements ranging from 1 Ω to 1800 Ω. Fifteen volunteers were measured with the prototype. We found that the left hemithorax has higher impedance compared to the right hemithorax, and the acquired signal presents the phases of the respiratory cycle with variations between 1 Ω, in normal breathing, to 6 Ω in maximum inhalation events. The system can measure the respiratory cycle variations simultaneously in both hemithorax with a mean error of -0.18 ± 1.42 BPM (breaths per minute) in the right hemithorax and -0.52 ± 1.31 BPM for the left hemithorax, constituting a useful device for the breathing rate calculation and possible screening applications.

Indexed as

Electric ImpedanceRespiratory RateWireless TechnologyElectrodesHumansMonitoring, Physiologicimpedance pneumographyrespirationwireless

Identifiers

PMID32937770
PMCPMC7571009
OpenAlexW3085173815

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked