Evidence map›Paper›PMID 32936487›Full record

ArticleMagnetic resonance in medicine2021

Model-based reconstruction for simultaneous multi-slice

Xiaoqing Wang, Sebastian Rosenzweig, Nick Scholand, H Christian M Holme, Martin Uecker

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.2field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Rapid 3D whole-brain high-resolution TMagnetic resonance in medicine · 2026
    Article
  4. Rapid, high-resolution and distortion-freeMagnetic resonance in medicine · 2025
    Article
  5. Article
  6. Article
  7. Repeatability and reproducibility of rapid TImaging neuroscience (Cambridge, Mass.) · 2025
    Article
  8. Article
  9. FastMagnetic resonance letters · 2024
    Article
  10. Article
  11. Simultaneous multislice cardiac multimapping based on locally low-rank and sparsity constraints.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Article
  12. Article
  13. Free-breathing myocardial TMagnetic resonance in medicine · 2023
    Article
  14. Cardiac MR: From Theory to Practice.Frontiers in cardiovascular medicine · 2022
    Review
  15. Physics-based reconstruction methods for magnetic resonance imaging.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Xiaoqing WangInstitute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany.ORCID 0000-0001-7036-7930
Sebastian RosenzweigInstitute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany.ORCID 0000-0001-7972-2134
Nick ScholandInstitute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany.ORCID 0000-0002-8876-0236
H Christian M HolmeInstitute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany.ORCID 0000-0002-8619-0444
Martin UeckerInstitute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany.ORCID 0000-0002-8850-809X
Universitätsmedizin Göttingen · DE

Funding

Interoperable Software Platform for Reproducible Research and Clinical Translation of MRIU24EB029240 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI LUSTIG, MICHAEL, UECKER, MARTIN · 2019 to 2023
$1.6M
NIBIB NIH HHS U24 EB029240
6 · The paper itself

Abstract

purposeTo develop a single-shot multi-slice

methodsSMS excitations are combined with a single-shot IR radial FLASH sequence for data acquisition. A previously developed single-slice calibrationless model-based reconstruction is extended to SMS, formulating the estimation of parameter maps and coil sensitivities from all slices as a single nonlinear inverse problem. Joint-sparsity constraints are further applied to the parameter maps to improve

resultsPhantom results confirm good

conclusionsThe IR SMS radial FLASH acquisition together with a nonlinear model-based reconstruction enable rapid high-resolution multi-slice

Indexed as

Image Processing, Computer-AssistedMagnetic Resonance ImagingAdultAlgorithmsBrainHumansPhantoms, Imagingmodel-based reconstructionradial FLASHsimultaneous multi-slice

Identifiers

PMID32936487
PMCPMC10409492
OpenAlexW3087197132

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.