ArticleCardiovascular intervention and therapeutics2021

Effectiveness of a radiation protective device for anesthesiologists and transesophageal echocardiography operators in structural heart disease interventions.

Hitoshi Miyazaki, Yoshiyuki Umezu, Emi Kinoshita, Kazuhisa Ogawa, Ken-Ichi Hiasa, Hiromichi Sonoda, Yuji Karashima, Toyoyuki Kato, Akira Shiose

Abstract read
PubMed Publisher
In one paragraph

Article in Cardiovascular intervention and therapeutics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hitoshi MiyazakiDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. mhitoshi@med.kyushu-u.ac.jp.
Yoshiyuki UmezuMedical Co, LTA Fukuoka Mirai Hospital, 3-5-1 Kashiiteriha, Higashi-ku, Fukuoka, 813-0017, Japan.
Emi KinoshitaDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Kazuhisa OgawaDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Ken-Ichi HiasaDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Hiromichi SonodaDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Yuji KarashimaOperating Rooms, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Toyoyuki KatoDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Akira ShioseDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In structural heart disease (SHD) interventions, the exposure of staff other than the first operator such as anesthesiologists and transesophageal echocardiography (TEE) operators to the radiation can also pose the risks of cancer and cataracts in the long term. This study was conducted to test our new radiation protective device (RPD) for anesthesiologists and TEE operators in SHD interventions. The RPD, which consists of a head side shield and a cradle shield, was mounted on a 0.25 mm Pb-equivalent unleaded radiation protection sheet on a self-made J-shaped acrylic table, and it was placed on the head side and cradle on the operating table. A CT human body phantom was placed on the operating table, and the C-arm was set in five directions: posteroanterior, right anterior oblique 30°, left anterior oblique 30°, caudal 30°, and cranial 30°. The ambient dose equivalent rate at the usual positions of the anesthesiologist and TEE operator were measured under a fluoroscopic sequence with and without the RPD, and the dose reduction rate was obtained. The height of each measurement point was set to 100, 130 or 160 cm. The reduction rates at the positions of the anesthesiologist and the TEE operator were 82.6-86.4% and 77.9-89.5% at the height of 100 cm, 48.5-68.4% and 83.3-91.0% at 130 cm, and 23.6-62.9% and 72.9-86.1% at 160 cm, respectively. The newly developed RPD can thus effectively reduce the radiation exposure of anesthesiologists and TEE operators during SHD interventions.

Indexed as

Heart DiseasesOccupational ExposureAnesthesiologistsEchocardiography, TransesophagealHumansProtective DevicesRadiation DosageAnesthesiologistRadiation exposureRadiation protectionRadiation protective deviceStructural heart disease interventionTransesophageal echocardiography operator