Validation of a Web-Based Planning Tool for Percutaneous Cryoablation of Renal Tumors.

Tim J van Oostenbrugge, Jan Heidkamp, Michael Moche, Phil Weir, Panchatcharam Mariappan, Ronan Flanigan, Mika Pollari, Stephen Payne, Marina Kolesnik, Sjoerd F M Jenniskens and 1 more

Abstract readValidation Study
In one paragraph

Article in Cardiovascular and interventional radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Tim J van OostenbruggeDepartment of Urology, Radboud University Medical Center, P.O. box 9101, 6500 HB, Nijmegen, The Netherlands. tim.vanoostenbrugge@radboudumc.nl.ORCID http://orcid.org/0000-0002-1614-6296
Jan HeidkampDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
Michael MocheDepartment of Diagnostic and Interventional Radiology, University Hospital, Leipzig, Germany.
Phil WeirNUMA Engineering Services Ltd, Dublin, Ireland.
Panchatcharam MariappanNUMA Engineering Services Ltd, Dublin, Ireland.
Ronan FlaniganNUMA Engineering Services Ltd, Dublin, Ireland.
Mika PollariDepartment of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland.
Stephen PayneDepartment of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford, UK.
Marina KolesnikFraunhofer - FIT - Institute for Applied Information Technology, Sankt-Augustin, Germany.
Sjoerd F M JenniskensDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
Jurgen J FüttererDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.

Funding

Seventh Framework Programme 600641
6 · The paper itself

Abstract

purposeTo validate a simulation environment for virtual planning of percutaneous cryoablation of renal tumors. MATERIALS AND

methodsProspectively collected data from 19 MR-guided procedures were used for validation of the simulation model. Volumetric overlap of the simulated ablation zone volume (Σ) and the segmented ablation zone volume (S; assessed on 1-month follow-up scan) was quantified. Validation metrics were DICE Similarity Coefficient (DSC; the ratio between twice the overlapping volume of both ablation zones divided by the sum of both ablation zone volumes), target overlap (the ratio between the overlapping volume of both ablation zones to the volume of S; low ratio means S is underestimated), and positive predictive value (the ratio between the overlapping volume of both ablation zones to the volume of Σ; low ratio means S is overestimated). Values were between 0 (no alignment) and 1 (perfect alignment), a value > 0.7 is considered good.

resultsMean volumes of S and Σ were 14.8 cm

conclusionThe validation results showed a tendency of the simulation model to overestimate the ablation effect. Model adjustments are necessary to make it suitable for clinical use.

Indexed as

InternetAgedAged, 80 and overCryosurgeryFemaleHumansKidney NeoplasmsMagnetic Resonance Imaging, InterventionalMaleMiddle AgedNeoplasm StagingTomography, X-Ray ComputedComputer-assisted image processingCryosurgeryIntraoperative monitoringKidney neoplasmsPreoperative care

Identifiers

PMID32935141
PMCPMC7591419

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.