Evidence map›Paper›PMID 32933492›Full record

ArticleBMC infectious diseases2020

Comparative performance study of three Ebola rapid diagnostic tests in Guinea.

Zelda Moran, William Rodriguez, Doré Ahmadou, Barré Soropogui, N' Faly Magassouba, Cassandra Kelly-Cirino, Yanis Ben Amor

Open access · goldAbstract readComparative Study
In one paragraph

Article in BMC infectious diseases, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
0.3field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Diagnostics of Ebola virus.Frontiers in public health · 2023
    Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 3 countries.

Zelda MoranCenter for Sustainable Development, Earth Institute, Columbia University, 475 Riverside Drive, Suite 1040, New York, NY, 10025, USA.
William RodriguezDraper Richards Kaplan Foundation, Menlo Park, CA, USA.
Doré AhmadouLaboratoire des Fièvres Hémorragiques en Guinée, Conakry, Guinea.
Barré SoropoguiLaboratoire des Fièvres Hémorragiques en Guinée, Conakry, Guinea.
N' Faly MagassoubaLaboratoire des Fièvres Hémorragiques en Guinée, Conakry, Guinea.
Cassandra Kelly-CirinoFoundation for Innovative New Diagnostics (FIND), Geneva, Switzerland.
Yanis Ben AmorCenter for Sustainable Development, Earth Institute, Columbia University, 475 Riverside Drive, Suite 1040, New York, NY, 10025, USA. yba2101@columbia.edu.ORCID http://orcid.org/0000-0003-1278-8715
Institut de Recherche Agronomique de Guinée · GNColumbia University · USDraper Richards Kaplan Foundation · USEarth Island Institute · USFIND · CH

Funding

Foundation for Innovative New Diagnostics PT-AABN1199
6 · The paper itself

Abstract

backgroundThe 2014/15 Ebola outbreak in West Africa resulted in 11,000 deaths and massive strain on local health systems, and the ongoing outbreak in Democratic Republic of Congo has afflicted more than 3000 people. Accurate, rapid Ebola diagnostics suitable for field deployment would enable prompt identification and effective response to future outbreaks, yet remain largely unavailable. The purpose of this study was to assess the accuracy of three novel rapid diagnostic tests (RDTs): an Ebola, an Ebola-Malaria, and a Fever Panel test that includes Ebola, all from a single manufacturer.

methodsWe evaluated the three RDTs in 109 Ebola-positive and 96 Ebola-negative stored serum samples collected during the outbreak in Guinea in 2014/15, and tested by real-time polymerase chain reaction (RT-PCR). Sensitivity, specificity, and overall percent agreement were calculated for each RDT using RT-PCR as a reference standard, stratified by Ct value ranges.

resultsAll tests performed with high accuracy on samples with low Ct value (high viral load). The Fever Panel test performed with the highest accuracy, with a sensitivity of 89.9% and specificity of 90.6%. The Ebola and Ebola-Malaria tests performed comparably to each other: sensitivity was 77.1 and 78% respectively, and specificity was 91.7% for the Ebola test and 95.8% for the Ebola-Malaria test.

conclusionsThis study evaluated the accuracy of three novel rapid diagnostic tests for Ebola. The tests may have significant public health relevance, particularly the Fever Panel test, which detects seven pathogens including Ebola. Given limitations to the study resulting from uncertain sample quality, further evaluation is warranted. All tests performed with highest accuracy on samples with low Ct value (high viral load), and the data presented here suggests that these RDTs may be useful for point-of-care diagnosis of cases in the context of an outbreak. Restrictions to their use in non-severe Ebola cases or for longitudinal monitoring, when viral loads are lower, may be appropriate. Highlighting the challenge in developing and evaluating Ebola RDTs, there were concerns regarding sample integrity and reference testing, and there is a need for additional research to validate these assays.

Indexed as

Point-of-Care SystemsDisease OutbreaksEbolavirusGuineaHemorrhagic Fever, EbolaHumansReagent Kits, DiagnosticReal-Time Polymerase Chain ReactionRNA, ViralSensitivity and SpecificityReagent Kits, DiagnosticRNA, ViralDiagnosticsEbolaGlobal HealthLaboratoryRapid diagnostic tests

Identifiers

PMID32933492
PMCPMC7493368
OpenAlexW3084568760

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.