Evidence map›Paper›PMID 32933160›Full record

ArticleMolecules (Basel, Switzerland)2020

Measurement of Glutathione as a Tool for Oxidative Stress Studies by High Performance Liquid Chromatography.

Faisal Nuhu, Andrew Gordon, Roger Sturmey, Anne-Marie Seymour, Sunil Bhandari

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers.

0numbers the graph read from it
0cells of the map it votes in
39citing papers in PubMed
3.5field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

39 citing papers in PubMed, 92 citations in OpenAlex.

  1. Trial
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Review
  17. Article
  18. Review
  19. Article
  20. NaRSC advances · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Faisal NuhuCentre for Atherothrombosis and Metabolic Disease, Hull York Medical School, University of Hull, Hull HU6 7RX, UK.
Andrew GordonCentre for Atherothrombosis and Metabolic Disease, Hull York Medical School, University of Hull, Hull HU6 7RX, UK.
Roger SturmeyCentre for Atherothrombosis and Metabolic Disease, Hull York Medical School, University of Hull, Hull HU6 7RX, UK.ORCID 0000-0003-4423-5058
Anne-Marie SeymourCentre for Atherothrombosis and Metabolic Disease, Hull York Medical School, University of Hull, Hull HU6 7RX, UK.
Sunil BhandariHull York Medical School & Department of Renal Medicine, Hull University Teaching Hospitals Trust, Anlaby Road, Kingston upon, Hull HU3 2JZ, UK.ORCID 0000-0002-0996-9622
University of Hull · GBHull York Medical School · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMaintenance of the ratio of glutathione in the reduced (GSH) and oxidised (GSSG) state in cells is important in redox control, signal transduction and gene regulation, factors that are altered in many diseases. The accurate and reliable determination of GSH and GSSG simultaneously is a useful tool for oxidative stress determination. Measurement is limited primarily to the underestimation of GSH and overestimation GSSG as a result of auto-oxidation of GSH. The aim of this study was to overcome this limitation and develop, optimise and validate a reverse-phase high performance liquid chromatographic (HPLC) assay of GSH and GSSG for the determination of oxidant status in cardiac and chronic kidney diseases.

methodsFluorescence detection of the derivative, glutathione-O-pthaldialdehyde (OPA) adduct was used. The assay was validated by measuring the stability of glutathione and glutathione-OPA adduct under conditions that could affect the reproducibility including reaction time and temperature. Linearity, concentration range, limit of detection (LOD), limit of quantification (LOQ), recovery and extraction efficiency and selectivity of the method were assessed.

resultsThere was excellent linearity for GSH (r

conclusionThese data validate a method for the simultaneous measurement of GSH and GSSG in samples extracted from biological tissues and offer a simple determination of redox status in clinical samples.

Indexed as

Oxidative StressAnimalsArginineBone and BonesChromatography, High Pressure LiquidGlutathioneHeartHydrogen PeroxideKidneyLimit of DetectionLiverMaleo-PhthalaldehydeOxidation-ReductionRats, Sprague-DawleyReactive Oxygen SpeciesArginineGlutathioneHydrogen Peroxideo-PhthalaldehydeReactive Oxygen SpeciesTissue Extractsglutathione analysisGSHGSSGHPLCoxidative stress

Identifiers

PMID32933160
PMCPMC7571047
OpenAlexW3084478303

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.