ArticleSensors (Basel, Switzerland)2020
Fabrication of Parylene-Coated Microneedle Array Electrode for Wearable ECG Device.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 45 citations in OpenAlex.
- Recent Advances in Portable Dry Electrode EEG: Architecture and Applications in Brain-Computer Interfaces.Sensors (Basel, Switzerland) · 2025Review
- Assessment of conductive textile-based electrocardiogram measurement for the development of a lonely death prevention system.Biomedical engineering letters · 2025Article
- Cutting-edge microneedle innovations: Transforming the landscape of cardiovascular and metabolic disease management.iScience · 2024Review
- Skin Comfort Sensation with Mechanical Stimulus from Electronic Skin.Materials (Basel, Switzerland) · 2024Article
- Advances in Printed Electronic Textiles.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Multichannel microneedle dry electrode patches for minimally invasive transdermal recording of electrophysiological signals.Microsystems & nanoengineering · 2024Article
- A study on the fabrication of metal microneedle array electrodes for ECG detection based on low melting point Bi-In-Sn alloys.Scientific reports · 2023Article
- Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring.NPJ digital medicine · 2023Review
- In Vivo Penetrating Microelectrodes for Brain Electrophysiology.Sensors (Basel, Switzerland) · 2022Review
- Potential of Microneedle Systems for COVID-19 Vaccination: Current Trends and Challenges.Pharmaceutics · 2022Review
- Recent Advances in Materials and Flexible Sensors for Arrhythmia Detection.Materials (Basel, Switzerland) · 2022Review
- Microneedle-Based Device for Biological Analysis.Frontiers in bioengineering and biotechnology · 2022Review
- A Real-Time Wearable Physiological Monitoring System for Home-Based Healthcare Applications.Sensors (Basel, Switzerland) · 2021Article
- Microneedle Array Electrode-Based Wearable EMG System for Detection of Driver Drowsiness through Steering Wheel Grip.Sensors (Basel, Switzerland) · 2021Article
- Special Issue: ECG Monitoring System.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
Microneedle array electrodes (MNE) showed immense potential for the sensitive monitoring of the bioelectric signals by penetrating the stratum corneum with high electrical impedance. In this paper, we introduce a rigid parylene coated microneedle electrode array and portable electrocardiography (ECG) circuit for monitoring of ECG reducing the motion artifacts. The developed MNE showed stability and durability for dynamic and long-term ECG monitoring in comparison to the typical silver-silver chloride (Ag/AgCl) wet electrodes. The microneedles showed no mechanical failure under the compression force up-to 16 N, but successful penetration of skin tissue with a low insertion force of 5 N. The electrical characteristics of the fabricated MNE were characterized by impedance spectroscopy with equivalent circuit model. The designed wearable wireless ECG monitoring device with MNE proved feasibility of the ECG recording which reduces the noise of movement artifacts during dynamic behaviors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.