Evidence map›Paper›PMID 32932608›Full record

ArticleMaterials (Basel, Switzerland)2020

Measurement of Internal Implantation Strains in Analogue Bone Using DVC.

Alexander Marter, Charles Burson-Thomas, Alexander Dickinson, Kathryn Rankin, Mark Mavrogordato, Fabrice Pierron, Martin Browne

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Alexander MarterBioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK.
Charles Burson-ThomasBioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK.ORCID 0000-0001-9308-4669
Alexander DickinsonBioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK.ORCID 0000-0002-9647-1944
Kathryn RankinµVIS X-ray Imaging Centre, University of Southampton, Southampton SO17 1BJ, UK.
Mark MavrogordatoµVIS X-ray Imaging Centre, University of Southampton, Southampton SO17 1BJ, UK.
Fabrice PierronMaterials Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK.
Martin BrowneBioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK.ORCID 0000-0001-5184-050X
University of Southampton · GB

Funding

Engineering and Physical Sciences Research Council EP/L505067/1Royal Academy of Engineering RF/130
6 · The paper itself

Abstract

The survivorship of cementless orthopaedic implants may be related to their initial stability; insufficient press-fit can lead to excessive micromotion between the implant and bone, joint pain, and surgical revision. However, too much interference between implant and bone can produce excessive strains and damage the bone, which also compromises stability. An understanding of the nature and mechanisms of strain generation during implantation would therefore be valuable. Previous measurements of implantation strain have been limited to local discrete or surface measurements. In this work, we devise a Digital Volume Correlation (DVC) methodology to measure the implantation strain throughout the volume. A simplified implant model was implanted into analogue bone media using a customised loading rig, and a micro-CT protocol optimised to minimise artefacts due to the presence of the implant. The measured strains were interpreted by FE modelling of the displacement-controlled implantation, using a bilinear elastoplastic constitutive model for the analogue bone. The coefficient of friction between the implant and bone was determined using the experimental measurements of the reaction force. Large strains at the interface between the analogue bone and implant produced localised deterioration of the correlation coefficient, compromising the ability to measure strains in this region. Following correlation coefficient thresholding (removing strains with a coefficient less than 0.9), the observed strain patterns were similar between the DVC and FE. However, the magnitude of FE strains was approximately double those measured experimentally. This difference suggests the need for improvements in the interface failure model, for example, to account for localised buckling of the cellular analogue bone structure. A further recommendation from this work is that future DVC experiments involving similar geometries and structures should employ a subvolume size of 0.97 mm as a starting point.

Indexed as

analogue bonecementless implantDigital Volume Correlation (DVC)FE modellingmicro-CT

Identifiers

PMID32932608
PMCPMC7559792
OpenAlexW3086982879

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked