Evidence map›Paper›PMID 32930908›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2021

Development and accuracy evaluation of a degree of occlusion visualization system for roller pumps used in cardiopulmonary bypass.

Aoi Fukaya, Yasuyuki Shiraishi, Yusuke Inoue, Akihiko Yamada, Genta Sahara, Takemi Kudo, Yasuhiro Aizawa, Tomoyuki Yambe

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Aoi FukayaGraduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan. aoi@ce.tbgu.ac.jp.ORCID http://orcid.org/0000-0001-8412-6636
Yasuyuki ShiraishiInstitute of Development, Aging and Cancer, Tohoku University, Miyagi, Japan. yasuyuki.shiraishi.d1@tohoku.ac.jp.
Yusuke InoueInstitute of Development, Aging and Cancer, Tohoku University, Miyagi, Japan.
Akihiko YamadaInstitute of Development, Aging and Cancer, Tohoku University, Miyagi, Japan.
Genta SaharaGraduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan.
Takemi KudoDepartment of Clinical Engineering, Faculty of Science and Technology, Tohoku Bunka Gakuen University, Miyagi, Japan.
Yasuhiro AizawaDepartment of Clinical Engineering, Faculty of Science and Technology, Tohoku Bunka Gakuen University, Miyagi, Japan.
Tomoyuki YambeGraduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan.
Tohoku Bunka Gakuen University · JPTohoku University · JPAsahikawa Medical University · JPTohoku Institute of Technology · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In roller pumps used for cardiopulmonary bypass (CPB), the degree of blockage within the tube resulting from compression of the tube by the rollers, or the degree of occlusion, is closely related to hemolysis, with both tight occlusive and non-occlusive degrees promoting hemolysis. There are as yet no international standards regarding methods of adjusting occlusiveness, and the amount of mechanical stress exerted upon blood remains unknown. To prevent hemolysis during CPB using roller pumps, there is a need to clarify and quantitatively assess the mechanical stress of the occlusiveness of the roller pump. In this study, we have developed a degree of occlusion quantification system which constructs the flow channel shape within an occluded tube from red optical density images, and we have verified the validity of this system. Utilizing a linear actuator, an acrylic roller and raceway, a solution colored with simulated blood powder, and a 3/8-inch vinyl chloride tube, this system uses a camera to capture red optical density images within an occluded tube and constructs the tube flow channel shape using a formula manipulation system. To verify the accuracy of this system, we compared the thickness of a cross-section of the flow channel constructed with the degree of occlusion quantification system with the thickness of a cross-section of silicone cured under the same occlusion conditions. Our experiments indicated that for areas with a small tube gap, this system can construct highly accurate three-dimensional shapes and obtain quantitative indicators assessing the degree of occlusion.

Indexed as

Optical DevicesCardiopulmonary BypassHemolysisHumansStress, MechanicalCardiopulmonary bypassDegree of occlusionHemolysisRoller pump

Identifiers

PMID32930908
OpenAlexW3086344684

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.