Evidence map›Paper›PMID 32930802›Full record

ArticleJournal of radiation research2020

Determination of reproducibility of end-exhaled breath-holding in stereotactic body radiation therapy.

Motoharu Sasaki, Hitoshi Ikushima, Kanako Sakuragawa, Michihiro Yokoishi, Akira Tsuzuki, Wataru Sugimoto

Abstract read
In one paragraph

Article in Journal of radiation research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Characterizing the motion management system accuracy on a 1.5T MR-Linac.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Motoharu SasakiDepartment of Therapeutic Radiology, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto-cho, Tokushima, Tokushima 770-8503, Japan.
Hitoshi IkushimaDepartment of Therapeutic Radiology, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto-cho, Tokushima, Tokushima 770-8503, Japan.
Kanako SakuragawaDepartment of Radiological Technology, Tokushima University Hospital, 2-50-1 Kuramoto-cho, Tokushima, Tokushima 770-8503, Japan.
Michihiro YokoishiDepartment of Radiological Technology, Tokushima University Hospital, 2-50-1 Kuramoto-cho, Tokushima, Tokushima 770-8503, Japan.
Akira TsuzukiDepartment of Radiological Technology, Kochi Medical School Hospital, 185-1 Kohasu, Oko-cho, Nankoku-shi, Kochi 783-8505, Japan.
Wataru SugimotoDepartment of Radiological Technology, Tokushima Prefectural Central Hospital, 1-10-3 Kuramoto-cho, Tokushima, Tokushima 770-8539, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Methods to evaluate the positional reproducibility of breath-hold irradiation mostly require manual operation. The purpose of this study is to propose a method to determine the reproducibility of breath-hold irradiation of lung tumors between fractions using non-artificial methods. This study included 13 patients who underwent terminal exhaled breath-hold irradiation for primary and metastatic lung cancer. All subjects received a prescribed dose of 60 Gy/8 fractions. The contours of the gross tumor volume (GTV) were extracted by threshold processing using treatment-planning computed tomography (CT) and cone-beam CT (CBCT), which was done just before the beginning of the treatment. The method proposed in this study evaluates the dice similarity coefficient (DSC) and Hausdorff distance (HD) by comparing two volumes, the GTVCTS (GTV obtained from treatment-planning CT) and GTVCBCT (GTV obtained from CBCT). The reference contours for DSC and HD are represented by GTVCTS. The results demonstrated good visual agreement for cases with a DSC of ~0.7. However, apparent misalignment occurred when the DSC was <0.5. HD was >2 mm in 3 out of 13 cases, and when the DSC was ~0.7, the HD was ~1 mm. In addition, cases with greater HD also demonstrated more significant variability. It was found that the DSC and HD evaluation methods for the positional reproducibility of breath-hold irradiation proposed in this study are straightforward and can be performed without the involvement of humans. Our study is of extreme significance in the field of radiation studies.

Indexed as

Breath HoldingAgedAged, 80 and overCone-Beam Computed TomographyFemaleHumansLungLung NeoplasmsMaleMiddle AgedNeoplasm MetastasisPatient PositioningRadiosurgeryRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedReproducibility of Resultsbreath-hold irradiationdice similarity coefficientHausdorff distancelung cancer

Identifiers

PMID32930802
PMCPMC7674682

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.