Evidence map›Paper›PMID 32930680›Full record

ArticleThe Analyst2020

Perturbation-induced high-frequency pulsing of nano-ESI with facile ion selection at atmospheric pressure.

William P McMahon, Kaveh Jorabchi

Abstract read
In one paragraph

Article in The Analyst, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

William P McMahonDepartment of Chemistry, Georgetown University, Washington, DC 20057, USA. kj256@georgetown.edu.
Kaveh Jorabchi

Funding

Next Generation Elemental Mass Spectrometry of Non-MetalsR01GM132112 · NIGMS · GEORGETOWN UNIVERSITY · PI Kaveh Jorabchi · 2019 to 2026
$1.7M
NIGMS NIH HHS R01 GM132112
6 · The paper itself

Abstract

Nano-ESI is a commonly used ionization technique with continually expanding analytical advantages. Here, we report a facile way for high-frequency (500-3800 Hz) pulsing of nano-ESI, providing a high flux of mobility-selected ions. The pulsing is accomplished using a relatively low-voltage modulation (80 V peak-to-peak) of an electrode placed <1 cm downstream of a nano-ESI emitter biased to a constant potential. Configuring the electrode as an ion gate enables mobility-based ion selection by scanning the modulation frequency. Our investigations indicate that the electrode modulation perturbs continuous nano-ESI, resulting in solution accumulation at the emitter tip between spray pulses. Selective transmission of ions occurs at frequencies corresponding to harmonics of a fundamental frequency determined by the travel time of each ion from the emitter to the ion gate (pulsing electrode). Remarkably, the intensities of ions selected in this fashion are similar across the harmonics, suggesting that the ionization efficiencies of analytes have minimal dependence on the accumulated volume at the emitter tip. Moreover, intensities of ion-mobility-selected analytes using this technique reach >50% of those in continuous nano-ESI without ion selection, underscoring efficient ion generation via high-frequency pulsing. These findings indicate the potential of the pulsed nano-ESI for enhanced analytical utility, such as a high-flux selected-reagent-ion supplier at atmospheric pressure, and chart new avenues to further enhance the analytical performance of nano-ESI.

Identifiers

PMID32930680
PMCPMC7655663

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.