Evidence map›Paper›PMID 32928260›Full record

ArticleJournal of orthopaedic surgery and research2020

Computational comparison of different plating strategies in medial open-wedge high tibial osteotomy with lateral hinge fractures.

Yen-Nien Chen, Chang-Han Chuang, Tai-Hua Yang, Chih-Wei Chang, Chun-Ting Li, Chia-Jung Chang, Chih-Han Chang

Open access · goldAbstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Yen-Nien ChenDepartment of Physical Therapy, Asia University, 500, Lioufeng Rd., Wufeng, Taichung, 41354, Taiwan. yennien.chen@gmail.com.ORCID http://orcid.org/0000-0002-3047-0797
Chang-Han ChuangDepartment of Orthopedics, Show Chwan Memorial Hospital, Changhua City, Taiwan.
Tai-Hua YangDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
Chih-Wei ChangDepartment of Orthopedics, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan. u7901064@yahoo.com.tw.
Chun-Ting LiInstitute of Geriatric Welfare Technology & Science, Mackay Medical College, New Taipei City, Taiwan.
Chia-Jung ChangDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
Chih-Han ChangDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
National Cheng Kung University Hospital · TWAsia University · TWChang Bing Show Chwan Memorial Hospital · TWMackay Medical University · TW

Funding

Show-Chwan Memorial Hospital NCKUSCMH10806
6 · The paper itself

Abstract

backgroundLateral hinge fracture (LHF) is associated with nonunion and plate breakage in high tibial osteotomy (HTO). Mechanical studies investigating fixation strategies for LHFs to restore stability and avoid plate breakage are absent. This study used computer simulation to compare mechanical stabilities in HTO for different LHFs fixed with medial and bilateral locking plates.

methodsA finite element knee model was created with HTO and three types of LHF, namely T1, T2, and T3 fractures, based on the Takeuchi classification. Either medial plating or bilateral plating was used to fix the HTO with LHFs. Furthermore, the significance of the locking screw at the combi hole (D-hole) of the medial TomoFix plate was evaluated.

resultsThe osteotomy gap shortening distance increased from 0.53 to 0.76, 0.79, and 0.72 mm after T1, T2, and T3 LHFs, respectively, with medial plating only. Bilateral plating could efficiently restore stability and maintain the osteotomy gap. Furthermore, using the D-hole screw reduced the peak stress on the medial plate by 28.7% (from 495 to 353 MPa), 26.6% (from 470 to 345 MPa), and 32.6% (from 454 to 306 MPa) in T1, T2, and T3 LHFs, respectively.

conclusionBilateral plating is a recommended strategy to restore HTO stability in LHFs. Furthermore, using a D-hole locking screw is strongly recommended to reduce the stress on the medial plate for lowering plate breakage risk.

Indexed as

Bone PlatesComputer SimulationBiomechanical PhenomenaBone ScrewsFinite Element AnalysisFracture Fixation, InternalHumansOsteotomyTibiaTibial FracturesFinite element simulationHigh tibial osteotomyLateral hinge fracturePlating strategy

Identifiers

PMID32928260
PMCPMC7489014
OpenAlexW3085624054

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.