Evidence map›Paper›PMID 32927651›Full record

ArticleSensors (Basel, Switzerland)2020

Contactless Capacitive Electrocardiography Using Hybrid Flexible Printed Electrodes.

Mathieu Lessard-Tremblay, Joshua Weeks, Laura Morelli, Glenn Cowan, Ghyslain Gagnon, Ricardo J Zednik

Abstract readLetter
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Unobtrusive Bed Monitor State of the Art.Sensors (Basel, Switzerland) · 2025
    Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mathieu Lessard-TremblayÉcole de Technologie Supérieure (ÉTS), Université du Québec, Montréal, QC H3C 1K3, Canada.
Joshua WeeksSIG.NUM Preemptive Healthcare, Inc., Montréal, QC H3K 1G6, Canada.
Laura MorelliÉcole de Technologie Supérieure (ÉTS), Université du Québec, Montréal, QC H3C 1K3, Canada.
Glenn CowanDepartment of Electrical and Computer Engineering, Concordia University, Montréal, QC H3G 1M8, Canada.
Ghyslain GagnonÉcole de Technologie Supérieure (ÉTS), Université du Québec, Montréal, QC H3C 1K3, Canada.ORCID 0000-0001-9484-7218
Ricardo J ZednikÉcole de Technologie Supérieure (ÉTS), Université du Québec, Montréal, QC H3C 1K3, Canada.ORCID 0000-0002-2767-2961

Funding

MEDTEQ 8-A_Contactless_ECG_V2Natural Sciences and Engineering Research Council of Canada CRDPJ 514369-17Natural Sciences and Engineering Research Council of Canada EGP2 492051-15
6 · The paper itself

Abstract

Traditional capacitive electrocardiogram (cECG) electrodes suffer from limited patient comfort, difficulty of disinfection and low signal-to-noise ratio in addition to the challenge of integrating them in wearables. A novel hybrid flexible cECG electrode was developed that offers high versatility in the integration method, is well suited for large-scale manufacturing, is easy to disinfect in clinical settings and exhibits better performance over a comparable rigid contactless electrode. The novel flexible electrode meets the frequency requirement for clinically important QRS complex detection (0.67-5 Hz) and its performance is improved over rigid contactless electrode across all measured metrics as it maintains lower cut-off frequency, higher source capacitance and higher pass-band gain when characterized over a wide spectrum of patient morphologies. The results presented in this article suggest that the novel flexible electrode could be used in a medical device for cECG acquisition and medical diagnosis. The novel design proves also to be less sensitive to motion than a reference rigid electrode. We therefore anticipate it can represent an important step towards improving the repeatability of cECG methods while requiring less post-processing. This would help making cECG a viable method for remote cardiac health monitoring.

Indexed as

ElectrocardiographyElectrodesElectric CapacitanceHumansMonitoring, PhysiologicMotioncapacitive electrocardiographyelectrode designflexible hybrid electronicsprinted electronicswearables

Identifiers

PMID32927651
PMCPMC7570869

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked