Evidence map›Paper›PMID 32922588›Full record

ArticleBiomicrofluidics2020

Analysis of pressure-driven membrane preconcentration for point-of-care assays.

A Drexelius, A Hoellrich, A Jajack, E Gomez, M Brothers, S Hussain, S Kim, J Heikenfeld

Open access · greenAbstract read
In one paragraph

Article in Biomicrofluidics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

A DrexeliusNovel Devices Laboratory, University of Cincinnati, Cincinnati, Ohio 45221, USA.
A HoellrichNovel Devices Laboratory, University of Cincinnati, Cincinnati, Ohio 45221, USA.
A JajackNovel Devices Laboratory, University of Cincinnati, Cincinnati, Ohio 45221, USA.
E GomezUES, Inc., Beavercreek, Ohio 45433, USA.
M Brothers711 Human Performance Wing, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, USA.
S Hussain711 Human Performance Wing, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, USA.
S Kim711 Human Performance Wing, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, USA.ORCID 0000-0002-9519-077X
J HeikenfeldNovel Devices Laboratory, University of Cincinnati, Cincinnati, Ohio 45221, USA.
University of Cincinnati · USWright-Patterson Air Force Base · USDefense Engineering Corporation (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Point-of-care diagnostic devices for both physicians and patients themselves are now ubiquitous, but often not sensitive enough for highly dilute analytes (e.g., pre-symptomatic viral detection). Two primary methods to address this challenge include (1) increasing the sensitivity of molecular recognition elements with greater binding affinity to the analyte or (2) increasing the concentration of the analyte being detected in the sample itself (preconcentration). The latter approach, preconcentration, is arguably more attractive if it can be made universally applicable to a wide range of analytes. In this study, pressure-driven membrane preconcentration devices were developed, and their performance was analyzed for detecting target analytes in biofluids in the form of point-of-care lateral-flow assays (LFAs). The demonstrated prototypes utilize negative or positive pressure gradients to move both water and small interferents (salt, pH) through a membrane filter, thereby concentrating the analyte of interest in the remaining sample fluid. Preconcentration up to 33× is demonstrated for influenza A nucleoprotein with a 5 kDa pore polyethersulfone membrane filter. LFA results are obtained within as short as several minutes and device operation is simple (very few user steps), suggesting that membrane preconcentration can be preferable to more complex and slow conventional preconcentration techniques used in laboratory practice.

Identifiers

PMID32922588
PMCPMC7467750
OpenAlexW3081857144

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.