The advantages of carbon fiber based orthopedic devices in patients who have to undergo radiotherapy.
Article in Acta bio-medica : Atenei Parmensis, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.
- Clinical performance of implanted devices used in surgical treatment of patients with spinal tumors: a systematic review.BMC musculoskeletal disorders · 2024Pooled it
- Soft tissue sarcomas of the proximal adductor area of the thigh: Indications, results and complications at medium follow-up in a series of 43 surgically treated patients.Journal of orthopaedics · 2024Article
- Multiple Myeloma (Part 2) - Update on The Approach to Bone Disease.Revista brasileira de ortopedia · 2023Article
- Complications of patients with bone tumors treated with carbon-fiber plates: an international multicenter study.Scientific reports · 2022Article
- A New Proximal Femur Reconstruction Technique after Bone Tumor Resection in a Very Small Patient: An Exemplificative Case.Children (Basel, Switzerland) · 2021Article
- The IlluminOss® photodynamic bone stabilization system for pathological osteolyses and fractures of the humerus: indications, advantages and limits in a series of 12 patients at 24 months of minimum follow-up.BMC musculoskeletal disorders · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND AND
objectivesThe modern approach to primary and secondary muscular skeletal tumors is multidisciplinary. The right combination of chemotherapy, surgery and radiotherapy (RT) makes obtaining local and distant disease control more likely. When surgery is indicated, radiotherapy often has a fundamental role as an adjuvant treatment; however, the titanium alloy instrumentations interfere with Radiotherapy setting, decreasing its effectiveness. It is common opinion that carbon fiber-reinforced devices are convenient in case of adjuvant RT in muscular skeletal oncology. The aim of the study is to support this intuition with experimental data, verifying the more accurate estimation of the delivered dose during RT, comparing Carbon Fiber-Reinforced PEEK (CFRP) plates with titanium-alloy orthopedic devices in order to evaluate their effects on target volume identification and dose distribution for radiation treatment.
methodsPhantoms were then irradiated with a linear accelerator Varian 2100 C/D with photon beams of 6 and 15 MV energies. Absorbed dose in the point of interest was verified by EBT3 gafchromic films above and below the two materials. Images from CT simulations were also analyzed in terms of Hounsfield numbers in patients with titanium and carbon fiber orthopedic implants in the spine or in the femur.
resultsFor a 6 MV photon beam, the doses measured just under the titanium-alloy plate were less than approximately 20% of the value calculated by the TPS. For a 15 MV beam energy, these differences were slightly lower. Using CFRP plate, the difference between measured and calculated doses was within ±3% for both energies, which was comparable with the statistical uncertainties. In the cases of simulated treatment of humerus titanium implants, the difference varies in range ± 10% with hot spot of + 10% and cold spot of -15%.
conclusionsThe use of CFRP for orthopedic devices and implants provides a valuable advantage in identifying the target due to the reduction of artifacts. Clear imaging of the soft tissues surrounding the bone is useful and reduces the discrepancies between calculated/delivered and measured doses, generating a more homogeneous dose distribution. Furthermore, there is a significant benefit in detecting the state of disease in CT imaging during the follow-up of treated patients. In-vivo studies are encouraged to verify whether a more effective radiotherapy leads to a decrease in local recurrence and local progression.