Evidence map›Paper›PMID 32915810›Full record

ArticlePloS one2020

Automatic unsupervised respiratory analysis of infant respiratory inductance plethysmography signals.

Carlos A Robles-Rubio, Robert E Kearney, Gianluca Bertolizio, Karen A Brown

Abstract readEvaluation Study
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Carlos A Robles-RubioDepartment of Biomedical Engineering, McGill University, Montreal, Quebec, Canada.
Robert E KearneyDepartment of Biomedical Engineering, McGill University, Montreal, Quebec, Canada.ORCID 0000-0002-5107-6190
Gianluca BertolizioDepartment of Anesthesia, Division of Pediatric Anesthesia, McGill University Health Centre, Montreal, Quebec, Canada.
Karen A BrownDepartment of Anesthesia, Division of Pediatric Anesthesia, McGill University Health Centre, Montreal, Quebec, Canada.ORCID 0000-0002-8093-844X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Infants are at risk for potentially life-threatening postoperative apnea (POA). We developed an Automated Unsupervised Respiratory Event Analysis (AUREA) to classify breathing patterns obtained with dual belt respiratory inductance plethysmography and a reference using Expectation Maximization (EM). This work describes AUREA and evaluates its performance. AUREA computes six metrics and inputs them into a series of four binary k-means classifiers. Breathing patterns were characterized by normalized variance, nonperiodic power, instantaneous frequency and phase. Signals were classified sample by sample into one of 5 patterns: pause (PAU), movement (MVT), synchronous (SYB) and asynchronous (ASB) breathing, and unknown (UNK). MVT and UNK were combined as UNKNOWN. Twenty-one preprocessed records obtained from infants at risk for POA were analyzed. Performance was evaluated with a confusion matrix, overall accuracy, and pattern specific precision, recall, and F-score. Segments of identical patterns were evaluated for fragmentation and pattern matching with the EM reference. PAU exhibited very low normalized variance. MVT had high normalized nonperiodic power and low frequency. SYB and ASB had a median frequency of respectively, 0.76Hz and 0.71Hz, and a mode for phase of 4o and 100o. Overall accuracy was 0.80. AUREA confused patterns most often with UNKNOWN (25.5%). The pattern specific F-score was highest for SYB (0.88) and lowest for PAU (0.60). PAU had high precision (0.78) and low recall (0.49). Fragmentation was evident in pattern events <2s. In 75% of the EM pattern events >2s, 50% of the samples classified by AUREA had identical patterns. Frequency and phase for SYB and ASB were consistent with published values for synchronous and asynchronous breathing in infants. The low normalized variance in PAU, was consistent with published scoring rules for pediatric apnea. These findings support the use of AUREA to classify breathing patterns and warrant a future evaluation of clinically relevant respiratory events.

Indexed as

Unsupervised Machine LearningApneaFemaleHumansInfantMalePlethysmographyPostoperative ComplicationsRespiratory MechanicsSignal Processing, Computer-Assisted

Identifiers

PMID32915810
PMCPMC7485851

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.