Evidence map›Paper›PMID 32915723›Full record

ArticleIEEE transactions on bio-medical engineering2021

Assessment of Collaborative Robot (Cobot)-Assisted Histotripsy for Venous Clot Ablation.

Kenneth B Bader, Samuel A Hendley, Viktor Bollen

Open access · hybridAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 23 citations in OpenAlex.

  1. Histotripsy: the first noninvasive, non-ionizing, non-thermal ablation technique based on ultrasound.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2021
    Pooled it
  2. Article
  3. Overview of Therapeutic Ultrasound Applications and Safety Considerations: 2024 Update.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025
    Review
  4. Insights fromInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2024
    Review
  5. Article
  6. Review
  7. An X-Ray C-Arm Guided Automatic Targeting System for Histotripsy.IEEE transactions on bio-medical engineering · 2023
    Article
  8. Article
  9. Histotripsy Ablation in Preclinical Animal Models of Cancer and Spontaneous Tumors in Veterinary Patients: A Review.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Review
  10. Clot Degradation Under the Action of Histotripsy Bubble Activity and a Lytic Drug.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Kenneth B Bader
Samuel A Hendley
Viktor Bollen
University of Chicago · USUniversity of Illinois Chicago · US

Funding

Treatment of chronic venous thrombosis with histotripsy and thrombolyticsR01HL133334 · NHLBI · UNIVERSITY OF CHICAGO · PI Kenneth B. Bader · 2018 to 2026
$5.7M
NHLBI NIH HHS R01 HL133334
6 · The paper itself

Abstract

objectiveThe application of bubble-based ablation with the focus ultrasound therapy histotripsy is gaining traction for the treatment of venous thrombosis, among other pathologies. For extensive clot burden, the histotripsy source must be translated to ensure uniform bubble activity throughout the vascular obstruction. The purpose of this study was to evaluate the targeting accuracy of a histotripsy system comprised of a focused source, ultrasound image guidance, and a collaborative robot (cobot) positioner. The system was designed with a primary emphasis for treating deep vein thrombosis.

methodsStudies to test treatment planning and targeting bubble activity with the histotripsy-cobot system were conducted in an in vitro clot model. A tissue-mimicking phantom was also targeted with the system, and the predicted and actual areas of liquefaction were compared to gauge the spatial accuracy of ablation.

resultsThe system provided submillimeter accuracy for both tracking along an intended path (within 0.6 mm of a model vessel) and targeting bubble activity within the venous clot model (0.7 mm from the center of the clot). Good correlation was observed between the planned and actual liquefaction locations in the tissue phantom, with an average Dice similarity coefficient of 77.8%, and average Hausdorff distance of 1.6 mm.

conclusionCobots provide an effective means to apply histotripsy pulses over a treatment volume, with the ablation precision contingent on the quality of image guidance. SIGNIFICANCE: Overall, these results demonstrate cobots can be used to guide histotripsy ablation for targets that extend beyond the natural focus of the transducer.

Indexed as

High-Intensity Focused Ultrasound AblationRoboticsThrombosisHumansPhantoms, ImagingTransducers

Identifiers

PMID32915723
PMCPMC8018710
OpenAlexW3084974172

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.