ArticleEuropean radiology experimental2020
Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT.
Article in European radiology experimental, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 35 citations in OpenAlex.
- Comparison of Iomeprol-400, Ultravist-370, and Omnipaque-350 in Preoperative Computed Tomography for Visualizing the Deep Inferior Epigastric Perforators.Plastic and reconstructive surgery. Global open · 2025Article
- Properties and antibacterial effectiveness of metal-ion doped borate-based bioactive glasses.Future microbiology · 2025Review
- Low Dose Contrast Enhanced CT Thorax Protocol: Comparison of Low Kilovoltage, Low Contrast Volume Using Iterative Reconstruction Technique with Standard Protocol.Ethiopian journal of health sciences · 2025Article
- Quantitative analysis of blooming artifact caused by calcification based on X-ray energy difference using computed tomography.Scientific reports · 2024Article
- An adult and pediatric size-based contrast administration reduction phantom study for single and dual-energy CT through preservation of contrast-to-noise ratio.Journal of applied clinical medical physics · 2024Article
- Percutaneous Intratumoral Immunoadjuvant Gel Increases the Abscopal Effect of Cryoablation for Checkpoint Inhibitor Resistant Cancer.Advanced healthcare materials · 2024Article
- Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics.Scientific reports · 2023Article
- Predicting Adverse Cardiac Events After Radiotherapy for Locally Advanced Non-Small Cell Lung Cancer.JACC. CardioOncology · 2023Article
- A Review on the Use of Imaging Biomarkers in Oncology Clinical Trials: Quality Assurance Strategies for Technical Validation.Tomography (Ann Arbor, Mich.) · 2023Review
- Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study.European radiology experimental · 2023Article
- Organic Compound with Potential for X-ray Imaging Applications.ACS omega · 2021Article
- Iodine-Loaded Calcium Titanate for Bone Repair with Sustainable Antibacterial Activity Prepared by Solution and Heat Treatment.Nanomaterials (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWe investigated the impact of varying contrast medium (CM) densities and x-ray tube potentials on contrast enhancement (CE), image quality and radiation dose in thoracic computed tomography (CT) using two different scanning techniques.
methodsSeven plastic tubes containing seven different CM densities ranging from of 0 to 600 HU were positioned inside a commercial chest phantom with padding, representing three different patient sizes. Helical scans of the phantom in single-source mode were obtained with varying tube potentials from 70 to 140 kVp. A constant volume CT dose index (CTDIvol) depending on phantom size and automatic dose modulation was tested. CE (HU) and image quality (contrast-to-noise ratio, CNR) were measured for all combinations of CM density and tube potential. A reference threshold of CE and kVp was defined as ≥ 200 HU and 120 kVp.
resultsFor the medium-sized phantom, with a specific CE of 100-600 HU, the diagnostic CE (200 HU) at 70 kVp was ~ 90% higher than at 120 kVp, for both scan techniques (p < 0.001). Changes in CM density/specific HU together with lower kVp resulted in significantly higher CE and CNR (p < 0.001). When changing only the kVp, no statistically significant differences were observed in CE or CNR (p ≥ 0.094), using both dose modulation and constant CTDIvol.
conclusionsFor thoracic CT, diagnostic CE (≥ 200 HU) and maintained CNR were achieved by using lower CM density in combination with lower tube potential (< 120 kVp), independently of phantom size.