ArticleBMC ophthalmology2020
Risk factors for exposure of Baerveldt glaucoma drainage implants: a case-control study.
Article in BMC ophthalmology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 5 citations in OpenAlex.
- Research Progress of Diabetes-related Glaucoma: Mechanisms, Impacts and Management Strategies.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026Review
- Risk factors for tube exposure following Baerveldt glaucoma implantation and overlying tissue thickness assessed by anterior segment optical coherence tomography.Japanese journal of ophthalmology · 2026Article
- Association between capsulectomy shunt revision and Ahmed glaucoma valve implant exposure--Shanghai Ahmed glaucoma valve implant exposure (AGVIE) study.BMC ophthalmology · 2026Article
- Extrusion-Free Survival Following Glaucoma Drainage Device Surgery Using EverPatch PlusJournal of clinical medicine · 2026Article
- Preliminary Surgical Outcomes of a Trimmed-Plate Aurolab Aqueous Drainage Implant (AADI) in Eyes at High Risk of Hypotony.Clinical ophthalmology (Auckland, N.Z.) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundGlaucoma drainage implant exposure is one of the serious complications after glaucoma drainage implant surgery. The purpose of this study is to evaluate the risk factors for exposure of the device after implantation of a Baerveldt glaucoma drainage implant.
methodsThis is a retrospective review of the medical records of all patients who underwent Baerveldt glaucoma drainage implant surgery at the Hiroshima University Hospital between April 1, 2012 and October 31, 2016, and who were followed for at least 6 months after surgery. We examined the risk factors for implant exposure based on data obtained from the medical records, with a particular focus on the differences in implant models.
resultsA total of 80 eyes from 80 patients were identified; all patients were Japanese. In this study, the rate of Baerveldt glaucoma drainage implant exposure was 15.0% (12 of 80 eyes). The exposure rate for the BG 102-350 tended to be higher than that for the BG 101-350 and BG 103-250 (p = 0.092; adjusted odds ratio = 3.34; 95% confidence interval, 0.82-13.58). In the patients who had diabetic mellitus, the BG 102-350 showed a significant risk of implant exposure (p = 0.038; adjusted odds ratio = 15.36; 95% confidence interval, 1.17-202.59).
conclusionsIn Baerveldt glaucoma drainage implant surgery in patients with diabetes, using the BG 102-350 was associated with greater risk of implant exposure compared with using the BG 101-350 or BG 103-250.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.