Evidence map›Paper›PMID 32906661›Full record

ArticleSensors (Basel, Switzerland)2020

Feasibility and Reliability of SmartWatch to Obtain 3-Lead Electrocardiogram Recordings.

Amirali Behzadi, Alireza Sepehri Shamloo, Konstantinos Mouratis, Gerhard Hindricks, Arash Arya, Andreas Bollmann

Registry-linked trialAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04092985 (Feasibility and Reliability of Smart Watch iECG for the Detection of Cardiac Arrhythmias), which is not on this map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04092985 completednot on this map

Feasibility and Reliability of Smart Watch iECG for the Detection of Cardiac Arrhythmias (The Leipzig Apple Heart Rhythm Study)

TypeobservationalSponsorHelios Health Institute GmbHRan2019 to 2021Enrolled500ConditionsArrhythmias, Cardiac, Atrial FibrillationArmsiECG recording
3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Advancing Digital Medicine with Wearables in the Wild.Sensors (Basel, Switzerland) · 2022
    Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Amirali BehzadiDepartment of Electrophysiology, Heart Center Leipzig at University of Leipzig, 04289 Leipzig, Germany.
Alireza Sepehri ShamlooDepartment of Electrophysiology, Heart Center Leipzig at University of Leipzig, 04289 Leipzig, Germany.
Konstantinos MouratisLeipzig Heart Digital at Leipzig Heart Institute, 04289 Leipzig, Germany.
Gerhard HindricksDepartment of Electrophysiology, Heart Center Leipzig at University of Leipzig, 04289 Leipzig, Germany.
Arash AryaDepartment of Electrophysiology, Heart Center Leipzig at University of Leipzig, 04289 Leipzig, Germany.
Andreas BollmannDepartment of Electrophysiology, Heart Center Leipzig at University of Leipzig, 04289 Leipzig, Germany.

Funding

Leipzig Heart Institute GmbH 2019-0157
6 · The paper itself

Abstract

Some of the recently released smartwatch products feature a single-lead electrocardiogram (ECG) recording capability. The reliability of obtaining 3-lead ECG with smartwatches is yet to be confirmed in a large study. This study aimed to assess the feasibility and reliability of smartwatch to obtain 3-lead ECG recordings, the classical Einthoven ECG leads I-III compared to standard ECG. To record lead I, the watch was worn on the left wrist and the right index finger was placed on the digital crown for 30 s. For lead II, the watch was placed on the lower abdomen and the right index finger was placed on the digital crown for 30 s. For lead III, the same process was repeated with the left index finger. Spearman correlation and Bland-Altman tests were used for data analysis. A total of 300 smartwatch ECG tracings were successfully obtained. ECG waves' characteristics of all three leads obtained from the smartwatch had a similar duration, amplitude, and polarity compared to standard ECG. The results of this study suggested that the examined smartwatch (Apple Watch Series 4) could obtain 3-lead ECG tracings, including Einthoven leads I, II, and III by placing the smartwatch on the described positions.

Indexed as

ElectrocardiographyWearable Electronic DevicesAngiotensin-Converting Enzyme InhibitorsAngiotensin Receptor AntagonistsFeasibility StudiesFemaleHumansMaleReproducibility of ResultsAngiotensin-Converting Enzyme InhibitorsAngiotensin Receptor AntagonistsApple Watchelectrocardiogramfeasibilitymobile healthreliabilitysmartwatchwearables

Identifiers

PMID32906661
PMCPMC7571061

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.