ArticleClinics in orthopedic surgery2020
Appropriateness of the Use of Navigation System in Total Knee Arthroplasty.
Article in Clinics in orthopedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 16 citations in OpenAlex.
- The Usefulness of a Simplified Navigation-Based Instrumentation for a Novice Surgeon in Primary Total Knee Arthroplasty: A Retrospective Analysis of a Randomized Controlled Trial.Clinics in orthopedic surgery · 2023Trial
- Long-term outcomes of computer-assisted Ci™ navigation versus conventional total knee arthroplasty.Joint diseases and related surgery · 2025Article
- Coronal plane femoral bowing in Far East Asians: implications for the strategy of distal femoral resection in total knee arthroplasty.Journal of orthopaedic surgery and research · 2022Article
- Comparison of Lower-Limb Alignment in Patients with Advanced Knee Osteoarthritis: EOS Biplanar Stereoradiography versus Conventional Scanography.Clinics in orthopedic surgery · 2022Article
- Preoperative Medial Tightness and Narrow Medial Joint Space Are Predictive Factors for Lower Extremity Alignment Change Toward Varus After Opening-Wedge High Tibial Osteotomy.Orthopaedic journal of sports medicine · 2022Article
- The position of entry point in total knee arthroplasty is associate with femoral bowing both in coronal and sagittal planes.Frontiers in surgery · 2022Article
- Notching is less, if femoral component sagittal positioning is planned perpendicular to distal femur anterior cortex axis, in navigated TKA.Knee surgery & related research · 2021Article
- Evaluation of the reliability of lower extremity alignment measurements using EOS imaging system while standing in an even weight-bearing posture.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroudThe aim of this study was to evaluate the difference between the planned and verified actual values in total knee arthroplasty (TKA) performed using a navigation system.
methodsSixty patients who underwent primary TKA for knee pain from March 2018 to July 2018 were included in this study. All patients underwent TKA using the latest version of a computer navigation system (Kick ver. 2.6). All TKA procedures were performed by the same surgeon. The appropriateness of the use of navigation system in each of the several steps during the operation was investigated. Implant size was assessed using a preoperative template and after registration of landmarks with the navigation system. Intraoperative measurement was conducted using a femoral sizing implant apparatus. The difference between the planned value based on the navigation system and the actual cutting value was investigated. Intraoperatively confirmed hip-knee-ankle angle was also compared to the angle measured at postoperative 3 months.
resultsThe average time spent on the registration process was 242 seconds (range, 205-345 seconds). Intraoperative femoral component size tended to be smaller than the size recommended by the navigation system. A significant difference between the planned distal femoral cutting level (9.08 ± 0.40 mm) and the verified actual cutting level (9.87 ± 1.39 mm) was identified (
conclusionsWhen performing navigation-assisted TKA, surgeons should aware that frequent errors can occur on the femoral cutting level, tibial cutting level, and implant sizing despite its reported advantage in defining the mechanical limb axis.