Evidence map›Paper›PMID 32903375›Full record

ArticleBMC biomedical engineering2019

Image improvement in linear-array photoacoustic imaging using high resolution coherence factor weighting technique.

Moein Mozaffarzadeh, Bahador Makkiabadi, Maryam Basij, Mohammad Mehrmohammadi

Abstract read
In one paragraph

Article in BMC biomedical engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Subaperture Processing-Based Adaptive Beamforming for Photoacoustic Imaging.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  7. Article
  8. Spatiotemporal Coherence Weighting for In Vivo Cardiac Photoacoustic Image Beamformation.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Moein MozaffarzadehResearch Center for Biomedical Technologies and Robotics, Institute for Advanced Medical Technologies, Tehran, Iran.
Bahador MakkiabadiResearch Center for Biomedical Technologies and Robotics, Institute for Advanced Medical Technologies, Tehran, Iran.
Maryam BasijDepartment of Biomedical Engineering, Wayne State University, Detroit, Michigan USA.
Mohammad MehrmohammadiDepartment of Biomedical Engineering, Wayne State University, Detroit, Michigan USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn Photoacoustic imaging (PAI), the most prevalent beamforming algorithm is delay-and-sum (DAS) due to its simple implementation. However, it results in a low quality image affected by the high level of sidelobes. Coherence factor (CF) can be used to address the sidelobes in the reconstructed images by DAS, but the resolution improvement is not good enough, compared to the high resolution beamformers such as minimum variance (MV). In this paper, it is proposed to use high-resolution-CF (HRCF) weighting technique in which MV is used instead of the existing DAS in the formula of the conventional CF.

resultsThe higher performance of HRCF is proved numerically and experimentally. The quantitative results obtained with the simulations show that at the depth of 40

conclusionProposed method provides a high resolution along with a low level of sidelobes for PAI.

Indexed as

Linear-array tomographyPhotoacoustic imagingResolution improvement

Identifiers

PMID32903375
PMCPMC7422598

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.