Evidence map›Paper›PMID 32902717›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2021

S-shaped titanium endomedullary nail reduces telescoping of comminuted midshaft clavicular fractures.

Ronny Langenhan, Stefanie Bushuven, Niklas Reimers, Axel Probst

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. New interlocking intramedullary nail for treating acute midshaft clavicular fractures in adults: A retrospective study.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ronny LangenhanDepartment of Orthopaedic Surgery, Hegau-Bodensee-Klinikum Singen, Virchowstrasse 10, 78224, Singen, Germany. ronnyla@gmx.de.ORCID http://orcid.org/0000-0002-7207-6720
Stefanie BushuvenDepartment of Orthopaedic Surgery, Hegau-Bodensee-Klinikum Singen, Virchowstrasse 10, 78224, Singen, Germany.
Niklas ReimersDepartment of Orthopaedic Surgery, Hegau-Bodensee-Klinikum Singen, Virchowstrasse 10, 78224, Singen, Germany.
Axel ProbstDepartment of Orthopaedic Surgery, Hegau-Bodensee-Klinikum Singen, Virchowstrasse 10, 78224, Singen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe surgical treatment of displaced midshaft clavicular fractures (DMCF) is clinically relevant and a much discussed topic. The axial stability of DMCF after intramedullary nailing (IMN) is still a matter of debate.

objectiveOur objective was to present a modification of IMN of DMCF with S-shaped titanium endomedullary nail (TEN) and determine fracture telescoping from day one after surgery to the time of fracture healing.

methodIn a prospective analytic cohort study over a 6-year period (2012-2017) at a Level II trauma care centre, a total of 128 patients with DMCF were included and classified according to the AO/OTA classification system. Group I was AO/OTA type 15.2A/15.2B (N = 68) and group II was AO/OTA type 15.2C (N = 60). After a modified open stabilization technique of each DMCF with IMN (S-shaped TEN), the dynamics of radiological assessed telescoping until union and rate of surgical adverse events were measured. Significance was assumed for p < 0.05.

resultsOne day after surgery, fractured clavicles were lengthened slightly in both groups compared to the unfractured clavicules (group I: 1.2%; group II: 0.9%). After osseus consolidation, the fractured clavicules were significantly shortened in both groups (group I: - 2.9%; group II: - 3.6%). Measurement of the clavicular shortening at one day postsurgically and at consolidation revealed a mean telescoping of - 3.99% in group I and of - 4.6% in group II. The difference between the two groups was not significant (P = 0.522). The overall rate of major surgical adverse events was 2.3%.

conclusionThe proposed operative technique of IMN (stabilization of the DMCF with a long, S-shaped, tight-fitting TEN) provides enough axial stability to prevent significant telescoping of the comminuted fractures. The rate of nonunion is low and the overall rate of major adverse events is similar to the reported events after plate fixation in the literature.

Indexed as

Fracture Fixation, IntramedullaryFractures, BoneFractures, ComminutedBone PlatesClavicleCohort StudiesFracture HealingHumansProspective StudiesTitaniumTreatment OutcomeTitaniumComminuted clavicular fractureDisplaced midshaft clavicular fractureIntramedullary nailingTelescoping

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.