Evidence map›Paper›PMID 32901769›Full record

ArticleRevista latino-americana de enfermagem2020

Assessment of the quality of a software application for the prevention of skin lesions in newborns.

Simone Vidal Santos, Flávia Regina Souza Ramos, Roberta Costa, Luís Manuel da Cunha Batalha

Open access · diamondAbstract read
In one paragraph

Article in Revista latino-americana de enfermagem, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
10.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 50 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Development of a mobile application for health education about sepsis.Revista da Escola de Enfermagem da U S P · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Simone Vidal SantosUniversidade Federal de Santa Catarina, Hospital Universitário, Florianópolis, SC, Brazil.ORCID http://orcid.org/0000-0002-5086-6326
Flávia Regina Souza RamosUniversidade Federal de Santa Catarina, Departamento de Enfermagem, Florianópolis, SC, Brazil.ORCID http://orcid.org/0000-0002-0077-2292
Roberta CostaUniversidade Federal de Santa Catarina, Departamento de Enfermagem, Florianópolis, SC, Brazil.ORCID http://orcid.org/0000-0001-6816-2047
Luís Manuel da Cunha BatalhaEscola Superior de Enfermagem de Coimbra, Unidade de Investigação em Ciências da Saúde: Enfermagem, Coimbra, Portugal.ORCID http://orcid.org/0000-0002-5328-1470
Universidade Federal de Santa Catarina · BREscola Superior de Enfermagem de Coimbra · PT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveto assess the technical quality of a mobile application to support the nurse's decision to prevent skin lesions in hospitalized newborns, according to the Product Quality Model.

methoda methodological study for technological assessment. The 20 evaluators, divided into two groups, 10 nurses and 10 information technology professionals, used the software, conducted tests based on two case studies, and evaluated six features and 23 sub-features of quality. The assessment was conducted by means of an online form. Data was analyzed through a specific formula and the items that obtained a concordance percentage over 70% were considered adequate.

resultsthe concordance percentages of the features in the groups of nurses and of information technology specialists were the following: functional adequacy (100%-98.9%), reliability (90%-100%), usability (93.2-85%), performance efficiency (100%-100%), compatibility (97.5-90%), and safety (94%-91%). In the assessment of the sub-features, only accessibility presented a percentage value below the desired one (70%-60%).

conclusionthe software has excellent technical quality to meet the needs of nurses in planning the care for the prevention of skin lesions of hospitalized newborns, brings important advances to neonatal care, contributes to the work process, expands knowledge, and promotes the professional's clinical reasoning.

Indexed as

Mobile ApplicationsHumansInfant, NewbornReproducibility of Results

Identifiers

PMID32901769
PMCPMC7478880
OpenAlexW3083944719

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.