Evidence map›Paper›PMID 32899893›Full record

ArticlePolymers2020

Imprinted Contact Lenses for Ocular Administration of Antiviral Drugs.

Angela Varela-Garcia, José Luis Gomez-Amoza, Angel Concheiro, Carmen Alvarez-Lorenzo

Open access · goldAbstract read
In one paragraph

Article in Polymers, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 44 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Review
  16. Soft Contact Lenses as Drug Delivery Systems: A Review.Molecules (Basel, Switzerland) · 2021
    Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Angela Varela-GarciaDepartamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma Group, Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain.
José Luis Gomez-AmozaDepartamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma Group, Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain.ORCID 0000-0001-7615-6616
Angel ConcheiroDepartamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma Group, Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain.ORCID 0000-0003-0507-049X
Carmen Alvarez-LorenzoDepartamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma Group, Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain.ORCID 0000-0002-8546-7085
Universidade de Santiago de Compostela · ES

Funding

Agencia Estatal de Investigación AEIEuropean Regional Development Fund FEDERMinisterio de Economía, Industria y Competitividad, Gobierno de España SAF2017-83118-RXunta de Galicia AEMAT ED431E 2018/08Xunta de Galicia ED431C 2016/008
6 · The paper itself

Abstract

A variety of ocular diseases are caused by viruses, and most treatments rely on the use of systemic formulations and eye drops. The efficient ocular barriers that oppose antiviral drug penetration have prompted the development of improved topical delivery platforms. The aim was to design hydrogel contact lenses endowed with an affinity for acyclovir (ACV) and its prodrug valacyclovir (VACV), first-choice drugs against herpes simplex virus (HSV) ocular keratitis, and that can sustain the release of therapeutic doses during daily wearing. Functional monomers suitable for interaction with these drugs were screened using computational modeling. Imprinted and non-imprinted hydrogels were prepared with various contents in the functional monomer methacrylic acid (MAA) and characterized in terms of swelling, transmittance, mechanical properties, and ocular compatibility (hen's egg test on chorioallantoic membrane (HET-CAM) assay). The values were in the range typical of soft contact lenses. Compared to ACV, the capability to load VACV was remarkably higher due to stronger electrostatic interactions with MAA. The advantages of the imprinting technology were evidenced for VACV. Stability of VACV loading solution/hydrogels under steam heat sterilization and subsequent drug release was investigated. Permeability studies through bovine and porcine cornea and sclera of the drug released from the hydrogels revealed that VACV accumulates in the cornea and can easily cross the sclera, which may facilitate the treatment of both anterior and posterior eye segments diseases.

Indexed as

antiviral drugcornea penetrationdrug-eluting contact lensmolecularly imprinted hydrogelsclera penetrationsustained release

Identifiers

PMID32899893
PMCPMC7565425
OpenAlexW3083674590

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.