ArticleSensors (Basel, Switzerland)2020
Integration and Testing of a Three-Axis Accelerometer in a Woven E-Textile Sleeve for Wearable Movement Monitoring.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 32 citations in OpenAlex.
- Skin sensing and wearable technology as tools to measure atopic dermatitis severity.Skin health and disease · 2024Review
- E-Textiles for Sports and Fitness Sensing: Current State, Challenges, and Future Opportunities.Sensors (Basel, Switzerland) · 2024Review
- Development of Joint Activity Angle Measurement and Cloud Data Storage System.Sensors (Basel, Switzerland) · 2022Article
- The E-Textile for Biomedical Applications: A Systematic Review of Literature.Diagnostics (Basel, Switzerland) · 2021Review
- Vibration-Sensing Electronic Yarns for the Monitoring of Hand Transmitted Vibrations.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
This paper presents a method to integrate and package an accelerometer within a textile to create an electronic textile (e-textile). The smallest commercially available accelerometer sensor (2 mm × 2 mm × 0.95 mm) is used in the e-textile and is fully integrated within the weave structure of the fabric itself, rendering it invisible to the wearer. The e-textile forms the basis of a wearable woven sleeve which is applied to arm and knee joint bending angle measurement. The integrated e-textile based accelerometer sensor system is used to identify activity type, such as walking or running, and count the total number of steps taken. Performance was verified by comparing measurements of specific elbow joint angles over the range of 0° to 180° with those obtained from a commercial bending sensor from Bend Labs and from a custom-built goniometer. The joint bending angles, measured by all three sensors, show good agreement with an error of less than ~1% of reading which provides a high degree of confidence in the e-textile sensor system. Subsequently, knee joint angles were measured experimentally on three subjects with each being tested three times on each of three activities (walking, running and climbing stairs). This allowed the minimum and maximum knee joint angles for each activity to be determined. This data is then used to identify activity type and perform step counting.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.