Evidence map›Paper›PMID 32895197›Full record

ArticleNan fang yi ke da xue xue bao = Journal of Southern Medical University2020

[Application of digital positioning guide plate in extraction of impacted supernumerary teeth].

Xianghuai Zheng, Xi Lin, Jinyou Chai, Rui Qi, Shuguang Liu

Open access · greenAbstract read
In one paragraph

Article in Nan fang yi ke da xue xue bao = Journal of Southern Medical University, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Xianghuai ZhengDepartment of Oral Surgery, Stomatological Hospital, Southern Medical University/ Guangdong Provincial Stomatological Hospital, Guangzhou 510280, China.
Xi LinDepartment of Implant, Stomatological Hospital, Southern Medical University/ Guangdong Provincial Stomatological Hospital, Guangzhou 510280, China.
Jinyou ChaiDepartment of Prosthodontics, Shenzhen stomatological Hospital, Southern Medical University, Shenzhen 518001, China.
Rui QiDepartment of Orthodontics, Stomatological Hospital, Southern Medical University/ Guangdong Provincial Stomatological Hospital, Guangzhou 510280, China.
Shuguang LiuDepartment of Oral Surgery, Stomatological Hospital, Southern Medical University/ Guangdong Provincial Stomatological Hospital, Guangzhou 510280, China.
Guangdong Province Stomatological Hospital · CNSouthern Medical University Shenzhen Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo explore the application of digital positioning guide plate in extraction of impacted supernumerary teeth and evaluate its clinical efficacy.

methodsFrom March to August, 2019, 30 patients with labial impacted supernumerary teeth treated in the Department of Oral and Maxillofacial Surgery, Stomatological Hospital, Southern Medical University were enrolled in this study. Fifteen of the patients were treated with digital positioning guide plate to remove the impacted supernumerary teeth (test group). According to the CBCT data and the dentition model of the patients, the positioning guide plate was positioned by avoiding the important anatomical structure with the tooth-bone surface as the support to design the soft tissue incision line and bone tissue exposure range. The other 15 patients who were treated without the use of the guide plate for operation served as the control group. The design time, tooth searching time, operation time and complications were compared between the two groups.

resultsThe positioning guide plate was well attached during the operation and allowed quick location of the supernumerary teeth while helping to expose the supernumerary teeth and avoid the damage of the adjacent important anatomical structures. The pre-operative design time was 50 ± 5 min in the test group and 0 min in the control group. The average time of tooth finding in the test group was 5±2 min, as compared with 10±3 min in the control group (

conclusionsThe application of digital positioning guide plate in extraction of embedded supernumerary teeth can significantly shorten the time of tooth finding, reduce the difficulty of operation, and improve the quality of operation.

Indexed as

Tooth, ImpactedTooth, SupernumeraryBone and BonesBone PlatesHumansOperative TimeTooth Extractiondigitalimpact toothminimal invasionsurgical guide

Identifiers

PMID32895197
PMCPMC7321273
OpenAlexW3084028801

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.