ArticleOrthopaedic surgery2020
Reduced Surgical Time and Higher Accuracy of Distal Locking with the Electromagnetic Targeting System in Humeral Shaft Intramedullary Nailing.
Article in Orthopaedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.
- Humeral shaft fracture: systematic review of non-operative and operative treatment.Archives of orthopaedic and trauma surgery · 2023Pooled it
- Rigid locked antegrade versus retrograde intramedullary nailing in treating acute humeral shaft fractures: a systematic review with meta-analysis.EFORT open reviews · 2026Article
- Does calibration technique for distal locking screw insertion reduce radiation exposure and operative time during intramedullary nailing of humeral shaft fractures in comparison with freehand technique?Surgery in practice and science · 2025Article
- Shoulder and Elbow Surgery Special Issue.Orthopaedic surgery · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo evaluate the efficacy of the electromagnetic distal targeting system in the treatment of humeral shaft fractures.
methodsFrom January 2012 to December 2018, we retrospectively reviewed 60 patients with humeral shaft fractures treated by intramedullary nailing. Among 60 cases, 41 were men and 19 were women. The average age at surgery was 48.5 years (range, 21-81 years). We performed the same surgical procedure for all patients. According to the different distal locking technique used, all patients were divided into two groups. The standard fluoroscopic freehand technique was used for Group FH, while the electromagnetic real-time targeting technique was used for Group EM. All procedures were performed by two senior surgeons. Overall surgical time, cases of complications, failure of distal locking, union time, and shoulder function assessment were recorded intraoperatively and during follow-up.
resultsTwenty-seven patients in Group FH and 33 patients in Group EM met the inclusion criteria. No significant difference was found in the demographic data of the two groups. The mean surgical time was 76.48 ± 10.73 min in Group FH and 65.61 ± 8.91 min in Group EM (P < 0.05), showing significant difference. Seven failures occurred in Group FH and two failures occurred in Group EM (P < 0.05). No relevant complications were noted. The average union time was 3.37 ± 0.49 months in Group FH and 3.39 ± 0.50 months in Group EM (P = 0.855). The mean follow-up was 14.30 ± 2.28 months in Group FH and 15.27 ± 2.83 months in Group EM (P = 0.153). The disabilities of the arm, shoulder and hand score (DASH) score, the range of motion (checked with the constant score), and the degree of functionality were, respectively, 21.52 ± 3.23, 27.04 ± 1.84, and 81.31% ± 3.88% in Group FH and 19.09 ± 2.40, 26.18 ± 1.70, and 77.97% ± 3.91% in Group EM (P = 0.233, 0.971, and 0.607).
conclusionThe electromagnetic real-time targeting system reduced surgical time and improved accuracy, and there was no radiation exposure in the distal locking procedure for humeral shaft fractures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.