Evidence map›Paper›PMID 32886270›Full record

ArticleJournal of medical systems2020

Quantitative Analysis Methods Using Histogram and Entropy for Detector Performance Evaluation According to the Sensitivity Change of the Automatic Exposure Control in Digital Radiography.

Jun-Ho Hwang, Kyung-Bae Lee, Ji-An Choi, Tae-Soo Lee

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jun-Ho HwangDepartment of Radiology, Kyung Hee University Medical Center, Seoul, 02447, South Korea.
Kyung-Bae LeeDepartment of Radiology, Kyung Hee University Medical Center, Seoul, 02447, South Korea.
Ji-An ChoiDepartment of Radiology, Kyung Hee University Medical Center, Seoul, 02447, South Korea.
Tae-Soo LeeDepartment of Biomedical Engineering Graduate School, Chungbuk National University, Cheongju-si, 28644, South Korea. tslee@chungbuk.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study is to evaluate detector performance using histogram and entropy analysis according to the sensitivity change of the automatic exposure control (AEC). The experiment was performed as follows: The sensitivity of the detector was analyzed through a normalized histogram with sensitivities of S200, S400, S800, and S1000 of the AEC; the entropy of the image was then analyzed, and the signal volume of the detector was evaluated according to the sensitivity change. As the sensitivity of the AEC was increased from S200 to S1000, the histogram showed underflow, quantization separation, and dynamic range discrepancy. In addition, entropy showed a decrease as sensitivity was set higher; in particular, entropy degradation was more prominent at sensitivities above S800. Through the histogram and entropy analysis, it was concluded that the detector does not reproduce the sensitivity and signal volume accurately when the sensitivity of the AEC is set high in performance evaluation.

Indexed as

Radiographic Image EnhancementEntropyHumansPhantoms, ImagingRadiation DosageAutomatic exposure control (AEC)DetectorDigital radiography (DR)EntropyHistogram

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked