Evidence map›Paper›PMID 32884254›Full record

ArticleInternational journal of chronic obstructive pulmonary disease2020

Association Between the Predictors of Functional Capacity and Heart Rate Off-Kinetics in Patients with Chronic Obstructive Pulmonary Disease.

Patrícia Faria Camargo, Luciana Ditomaso-Luporini, Luiz Carlos Soares de Carvalho, Cássia da Luz Goulart, Rayane Sebold, Polliana Batista Dos Santos, Meliza Goi Roscani, Audrey Borghi-Silva

Open access · goldAbstract read
In one paragraph

Article in International journal of chronic obstructive pulmonary disease, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Patrícia Faria CamargoCardiopulmonary Physiotherapy Laboratory, Physiotherapy Department, Federal University of Sao Carlos, Sao Paulo, Brazil.ORCID 0000-0002-6564-1672
Luciana Ditomaso-LuporiniCardiopulmonary Physiotherapy Laboratory, Physiotherapy Department, Federal University of Sao Carlos, Sao Paulo, Brazil.ORCID 0000-0003-1609-6492
Luiz Carlos Soares de CarvalhoCenter for Science and Technology in Energy and Sustainability of Federal University of Reconcavo da Bahia, Feira de Santana, Bahia, Brazil.ORCID 0000-0001-9040-7282
Cássia da Luz GoulartCardiopulmonary Physiotherapy Laboratory, Physiotherapy Department, Federal University of Sao Carlos, Sao Paulo, Brazil.ORCID 0000-0001-8731-689X
Rayane SeboldCardiopulmonary Physiotherapy Laboratory, Physiotherapy Department, Federal University of Sao Carlos, Sao Paulo, Brazil.ORCID 0000-0003-0444-9705
Polliana Batista Dos SantosCardiopulmonary Physiotherapy Laboratory, Physiotherapy Department, Federal University of Sao Carlos, Sao Paulo, Brazil.ORCID 0000-0003-3354-8913
Meliza Goi RoscaniMedicine Department, Federal University of Sao Carlos, Sao Carlos, Sao Paulo, Brazil.ORCID 0000-0003-1463-551X
Audrey Borghi-SilvaCardiopulmonary Physiotherapy Laboratory, Physiotherapy Department, Federal University of Sao Carlos, Sao Paulo, Brazil.ORCID 0000-0002-3891-6941
Universidade Federal de São Carlos · BRUniversidade Federal do Recôncavo da Bahia · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The heart rate (HR) kinetics as well as other predictors of functional capacity such as the Chronic Obstructive Pulmonary Disease (COPD) Assessment Test (CAT), the Duke Activity Status Index (DASI) and the handgrip strength (HGS) represent important tools in assessing the impact of COPD on exercise performance and health status of individuals with COPD. Purpose: To verify the relationship between functional capacity, measured using the six-minute walking test (6MWT), with the HR off-kinetics, HGS and the DASI and CAT scores. Methods: For this cross-sectional study, 29 subjects with COPD underwent body composition, pulmonary function and cardiac function tests. Subsequently, the DASI and CAT questionnaires and HGS test were performed. The beat-to-beat R-R intervals (IRR) were collected in rest, during the test and in recovery after the 6MWT. The HR off-kinetics was obtained during a 360-second period in post-exercise recovery through the HR mono-exponential decay. Results: Moderate correlations were observed between: 1) walked distance (WD) in the 6MWT and the CAT and DASI scores (r= -0.58, p=0.001 and r= 0.58, p=0.001, respectively); 2) WD and HGS (r=0.37, p=0.05); 3) and WD and HR off-kinetics (τ; r= -0.54, p=0.002 and MRT; r= -0.55, p=0.002, respectively). Conclusion: The 6MWT performance is a direct measurement to evaluate functional capacity. Additionally, it is related to other direct and indirect markers for functional evaluation in patients with COPD. These results suggest the application of these tools in clinical practice, based on the accessibility, non-invasive character and easy applicability of these methods.

Indexed as

Pulmonary Disease, Chronic ObstructiveCross-Sectional StudiesExercise TestExercise ToleranceHand StrengthHeart RateHumansKineticsCOPDexercisekineticsquestionnaires

Identifiers

PMID32884254
PMCPMC7438181
OpenAlexW3048605989

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.