Evidence map›Paper›PMID 32883781›Full record

ArticleJournal of neurointerventional surgery2021

The novel Tenzing 7 delivery catheter designed to deliver intermediate catheters to the face of embolus without crossing: clinical performance predicted in anatomically challenging model.

Andreas Maximilian Frölich, Warren Kim, Knut Stribrny, Olav Jansen, Markus Möhlenbruch, Istvan Szikora, Fritz Wodarg, Jens Fiehler, Kim Otto, Tony Chou and 2 more

Abstract read
In one paragraph

Article in Journal of neurointerventional surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Improved catheter delivery for aspiration thrombectomy using Tenzing 7 ledge reducing catheter and FreeClimb 70.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  3. Tenzing 7 delivery catheter with or without a leading microwire for single pass aspiration thrombectomy: A multicenter experience.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  4. The Aristotle 18 and 24 microwires in neuroIntervention: Early experience at a single centre.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Combined technique as first approach in mechanical thrombectomy: Efficacy and safety of REACT catheter combined with stent retriever.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023
    Article
  15. Article
  16. Review
  17. A Review of the Advancements in theFrontiers in medical technology · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Andreas Maximilian FrölichDepartment of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany a.froelich@uke.de.ORCID http://orcid.org/0000-0002-0804-1056
Warren KimRadiology, California Pacific Medical Center, San Francisco, California, USA.
Knut StribrnyDepartment of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Olav JansenDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein Campus Kiel, Kiel, Schleswig-Holstein, Germany.
Markus MöhlenbruchNeuroradiology, University Hospital Heidelberg, Heidelberg, Baden-Württemberg, Germany.
Istvan SzikoraNeurointerventions, National Institute of Neurosciences, Budapest, Hungary.ORCID http://orcid.org/0000-0003-3730-3278
Fritz WodargDepartment of Radiology and Neuroradiology, Universitatsklinikum Schleswig-Holstein Campus Kiel, Kiel, Germany.ORCID http://orcid.org/0000-0003-1413-2699
Jens FiehlerDepartment of Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Hamburg, Germany.
Kim OttoRoute 92 Medical, Inc, San Mateo, California, USA.
Tony ChouRoute 92 Medical, Inc, San Mateo, California, USA.
Jan Hendrik BuhkDepartment of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Joey EnglishRadiology, California Pacific Medical Center, San Francisco, California, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn large vessel occlusionstroke, navigation of aspiration catheters (AC) can be impeded by vessel tortuosity and the ophthalmic artery origin. A novel tapered delivery catheter was designed to facilitate delivery without disturbing the embolus. We assessed AC deliverability in vitro and validated the observations in a first-in-human experience.

methodsIn a vascular model with three challenging craniocervical scenarios, two commercial AC were advanced from the carotid to the middle cerebral artery by four neurointerventionalists. Catheter deliverability with standard microwire and microcatheter (MC) combinations and the Tenzing 7 (T7) Delivery Catheter (Route 92 Medical, San Mateo, CA) were compared. Operators rated aspects of catheter deliverability on a 5-point scale. Results were compared with device delivery patterns at a neurovascular center before and after clinical introduction of T7.

resultsIn vitro, success rate and speed were higher with T7 (96%; mean 30±10 s) than with MC (65%; 72±47 s, p<0.001 each), with fewer interactions with the occlusion site (T7: 54% vs MC: 77%, p=0.004). T7 received superior ratings regarding carotid artery deflection (T7: 2, IQR1-3 vs MC: 3, IQR2-3, p<0.001), guide catheter pushback (T7: 2, IQR1-3 vs MC: 3, IQR3-3, p<0.001) and ophthalmic artery passage (T7: 1.5, IQR1-2 vs MC: 4, IQR3-5, p<0.001). Before introduction of T7 at a single center, delivery of AC to a large vessel occlusion without crossing was achieved in 15/123 cases (12%). With T7, this rate was 28/31 patients (90.3%).

conclusionCompared with microcatheter and microwire combinations, T7 improves aspiration catheter delivery in vitro, minimizing the need to cross the occlusion. Initial clinical experience appears to validate the model's observations.

Indexed as

CathetersCerebral RevascularizationEquipment DesignIntracranial EmbolismIschemic StrokeThrombectomyCarotid ArteriesHumansMaterials TestingMiddle Cerebral ArteryRetrospective StudiesTreatment Outcomecatheterguidewireinterventionstrokethrombectomy

Identifiers

PMID32883781
PMCPMC8292588

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.