Evidence map›Paper›PMID 32880792›Full record

ArticleEJNMMI physics2020

From a PMT-based to a SiPM-based PET system: a study to define matched acquisition/reconstruction parameters and NEMA performance of the Biograph Vision 450.

Thomas Carlier, Ludovic Ferrer, Maurizio Conti, Caroline Bodet-Milin, Caroline Rousseau, Yanic Bercier, Bernard Bendriem, Françoise Kraeber-Bodéré

Abstract read
In one paragraph

Article in EJNMMI physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Development of a Prototype AWSM-PET Device for Augmented Whole-Body PET Imaging and Initial Human Study.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Comparison of Digital versus AnalogDiagnostics (Basel, Switzerland) · 2023
    Article
  7. Article
  8. Article
  9. Phantom-based evaluation of yttrium-90 datasets using biograph vision quadra.European journal of nuclear medicine and molecular imaging · 2023
    Article
  10. Article
  11. The effect of modern PET technology and techniques on the EANM paediatric dosage card.European journal of nuclear medicine and molecular imaging · 2022
    Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Thomas CarlierNuclear Medicine Department, University Hospital of Nantes, Place Alexis Ricordeau, Nantes, France. thomas.carlier@chu-nantes.fr.ORCID http://orcid.org/0000-0002-6932-7322
Ludovic FerrerUniversité de Nantes, CNRS, INSERM, CRCINA, Nantes, France.
Maurizio ContiSiemens Medical Solutions USA, Inc., Knoxville, TN, USA.
Caroline Bodet-MilinNuclear Medicine Department, University Hospital of Nantes, Place Alexis Ricordeau, Nantes, France.
Caroline RousseauUniversité de Nantes, CNRS, INSERM, CRCINA, Nantes, France.
Yanic BercierSiemens Medical Solutions USA, Inc., Knoxville, TN, USA.
Bernard BendriemSiemens Medical Solutions USA, Inc., Knoxville, TN, USA.
Françoise Kraeber-BodéréNuclear Medicine Department, University Hospital of Nantes, Place Alexis Ricordeau, Nantes, France.

Funding

Labex IRON French National Agency for Research called "Investissements d'Avenir" IRON Labex n° ANR-11-LABX-0018-01SIRIC ILIAD INCa-DGOS-Inserm_12558
6 · The paper itself

Abstract

backgroundThe purpose of this work was to propose an approach based on noise measurement to adapt present clinical acquisition and reconstruction parameters adapted to a PMT-based system (Biograph mCT) to a SiPM-based system (Biograph Vision 450) sharing identical geometrical properties. The NEMA performance (NEMA) of the recently released Biograph Vision 450 PET/CT (Vision) was also derived.

methodsAll measurements were conducted on Vision and Biograph mCT with TrueV (mCT). A full NEMA-based performance was derived for Vision only. The adaptation of acquisition and reconstruction parameters from mCT to Vision was done using the NEMA image quality phantom. The noise level reached using mCT was set as the reference value for six different numbers of net true coincidences. The noise level computed using Vision was matched to the reference noise level (within 0.01%) using a different reconstruction set-up to determine the potential reduction of count numbers for the same noise level.

resultsVision sensitivity was 9.1 kcps/MBq for a timing resolution of 213 ps at 5.3 kBq/mL. The NEMA-based CR for the 10-mm sphere was better than 75% regardless the reconstruction set-up studied. The mCT reference noise properties could be achieved using Vision with a scan time reduction (STR) of 1.34 with four iterations and a 440 × 440 matrix size (or STR = 1.89 with a 220 × 220 matrix size) together with a 3D CR improvement of 53% for the 10-mm sphere (24% using 220 × 220).

conclusionThe Vision exhibited improved NEMA performances compared to mCT. Using the proposed approach, the time acquisition could be divided by almost two, while keeping the same noise properties as that of mCT with a marked improvement of contrast recovery.

Indexed as

NEMANoiseOptimizationVision 450

Identifiers

PMID32880792
PMCPMC7471223

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked