Evidence map›Paper›PMID 32880736›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2021

Intraoperative quantification of floating mass transducer coupling quality in active middle ear implants: a multicenter study.

Laura Fröhlich, Torsten Rahne, Stefan K Plontke, Tobias Oberhoffner, Rüdiger Dahl, Robert Mlynski, Oliver Dziemba, Aristotelis Aristeidou, Maria Gadyuchko, Sven Koscielny and 4 more

Abstract readMulticenter Study
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Intraoperative ABR in Vibrant Soundbridge Surgery: Influence of Bone-Conduction Thresholds.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Article
  2. Article
  3. Early activation of active middle ear implants: a prospective study.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025
    Article
  4. Intraoperative ABR measurements via the active middle ear implant vibrant soundbridge using different types of couplers.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025
    Article
  5. The influence of intraoperative auditory brainstem responses on vibroplasty coupling-quality and analysis of the impact of different fixation steps on the coupling.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024
    Article
  6. Article
  7. Long-term outcomes of retrospective case series of middle ear implantation with Vibrant Soundbridge in children with congenital aural atresia.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2023
    Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Laura FröhlichDepartment of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, University Medicine Halle (Saale), Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany. laura.froehlich@uk-halle.de.ORCID http://orcid.org/0000-0002-7826-8491
Torsten RahneDepartment of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, University Medicine Halle (Saale), Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany.
Stefan K PlontkeDepartment of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, University Medicine Halle (Saale), Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany.
Tobias OberhoffnerDepartment of Otorhinolaryngology, Head and Neck Surgery "Otto Körner", Rostock University Medical Center, Rostock, Germany.
Rüdiger DahlDepartment of Otorhinolaryngology, Head and Neck Surgery "Otto Körner", Rostock University Medical Center, Rostock, Germany.
Robert MlynskiDepartment of Otorhinolaryngology, Head and Neck Surgery "Otto Körner", Rostock University Medical Center, Rostock, Germany.
Oliver DziembaDepartment of Otorhinolaryngology, Head and Neck Surgery, University Medicine of Greifswald, Greifswald, Germany.
Aristotelis AristeidouDepartment of Otorhinolaryngology, Head and Neck Surgery, University Medicine of Greifswald, Greifswald, Germany.
Maria GadyuchkoDepartment of Otorhinolaryngology, Institute of Phoniatry/Pedaudiology, Jena University Hospital, Friedrich-Schiller-University Jena, Jena, Germany.
Sven KoscielnyDepartment of Otorhinolaryngology, Institute of Phoniatry/Pedaudiology, Jena University Hospital, Friedrich-Schiller-University Jena, Jena, Germany.
Sebastian HothDepartment of ENT, University of Heidelberg, Heidelberg, Germany.
Miriam H KroppORL Department Friedrichshain Clinic, Vivantes Hearing Center, Berlin, Germany.
Parwis Mir-SalimORL Department Friedrichshain Clinic, Vivantes Hearing Center, Berlin, Germany.
Alexander MüllerORL Department Friedrichshain Clinic, Vivantes Hearing Center, Berlin, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEvaluating the effectiveness of intraoperative auditory brainstem responses (ABRs) to stimulation by the Vibrant Soundbridge (VSB) active middle ear implant for quantifying the implant's floating mass transducer (FMT) coupling quality.

methodsIn a diagnostic multicentric study, patients (> 18 years) who received a VSB with different coupling modalities were included. Pre- and postoperative bone conduction thresholds, intraoperative VSB-evoked ABR thresholds (VSB-ABR) using a modified audio processor programmed to preoperative bone conduction thresholds, postoperative vibrogram thresholds, and postoperative VSB-ABR thresholds were measured. Coupling quality was calculated from the difference between the pure tone average at 1000, 2000, and 4000 Hz (3PTA) vibrogram and postoperative 3PTA bone conduction thresholds.

resultsTwenty-three patients (13 males, 10 females, mean age 56.6 (± 12.5) years) were included in the study. Intraoperative VSB-ABR response thresholds could be obtained in all except one patient where the threshold was > 30 dB nHL. Postoperatively, an insufficient coupling of 36.7 dB was confirmed in this patient. In a Bland-Altman analysis of the intraoperative VSB-ABRs and coupling quality, the limits of agreement exceeded ± 10 dB, i.e., the maximum allowed difference considered as not clinically important but the variation was within the general precision of auditory brainstem responses to predict behavioral thresholds. Five outliers were identified. In two patients, the postoperative VSB-ABR thresholds were in agreement with the coupling quality, indicating a change of coupling before the postoperative testing.

conclusionThe response thresholds recorded in this set-up have the potential to predict the VSB coupling quality and optimize postoperative audiological results.

Indexed as

Hearing Loss, Mixed Conductive-SensorineuralOssicular ProsthesisAuditory ThresholdBone ConductionEvoked Potentials, Auditory, Brain StemFemaleHumansMaleMiddle AgedTransducersActive middle ear implantCoupling qualityFloating mass transducerIntraoperativeObjective measures

Identifiers

PMID32880736
PMCPMC8165065

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.