ArticleSurgery today2021
The usefulness and utilization of a detachable steel wire-rimmed retractor (KN retractor) for endoscopic thyroid and parathyroid surgery.
Article in Surgery today, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
purposeIn endoscopic surgery, surgeons occasionally encounter difficulties due to visual field obstruction by muscles or blood vessels. In these situations, specialized instruments that can effectively retract these obstructions are required. Recently, we developed a new detachable wire-rimmed retractor (KN retractor) for narrow-space surgery.
methodsWe evaluated the utility of this KN retractor in 15 patients with thyroid and parathyroid disease. Of those, five patients with papillary thyroid cancer had gasless endoscopic hemithyroidectomy with central node dissection, five underwent endoscopic total thyroidectomy for Graves' disease, and the remaining five received endoscopic parathyroidectomy with gas insufflation.
resultsSurgeons were able to perform meticulous operations in a satisfactory visual field supported by the KN retractor. In all patients, the strap muscles were preserved without cutting. The average operating time was 149, 154, and 81 min in patients who underwent hemithyroidectomy with central node dissection, total thyroidectomy, and parathyroidectomy, respectively. Gas insufflation was successfully completed in all cases while maintaining sufficient airtightness.
conclusionsThe KN retractor is suitable for both the gasless lifting method and gas insufflation surgery in a narrow space. We believe that the KN retractor is a new device that will greatly improve the safety and shorten the operation time in endoscopic surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.