Intradevice Repeatability and Interdevice Agreement of Ocular Biometric Measurements: A Comparison of Two Swept-Source Anterior Segment OCT Devices.

Anmol A Pardeshi, Abe E Song, Naim Lazkani, Xiaobin Xie, Alex Huang, Benjamin Y Xu

Abstract read
In one paragraph

Article in Translational vision science & technology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Observational
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Anmol A PardeshiUSC Roski Eye Institute, Department of Ophthalmology, Keck School of Medicine at the University of Southern California, Los Angeles, CA, USA.
Abe E SongUSC Roski Eye Institute, Department of Ophthalmology, Keck School of Medicine at the University of Southern California, Los Angeles, CA, USA.
Naim LazkaniUSC Roski Eye Institute, Department of Ophthalmology, Keck School of Medicine at the University of Southern California, Los Angeles, CA, USA.
Xiaobin XieEye Hospital of China Academy of Chinese Medical Sciences, Beijing, China.
Alex HuangDoheny Eye Institute and Department of Ophthalmology, David Geffen School of Medicine at University of California Los Angeles, Los Angeles, CA, USA.
Benjamin Y XuUSC Roski Eye Institute, Department of Ophthalmology, Keck School of Medicine at the University of Southern California, Los Angeles, CA, USA.

Funding

Southern California Clinical and Translational Science InstituteUL1TR001855 · NCATS · UNIVERSITY OF SOUTHERN CALIFORNIA · PI Thomas A Buchanan, Michele D. Kipke · 2016 to 2026
$81.3M
Ophthalmic Therapeutics Engineering CoreP30EY029220 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI Qifa Zhou · 2018 to 2026
$6.5M
Dynamic Variable Aqueous Humor Outflow and Glaucoma Therapies in the Human EyeR01EY030501 · NEI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI Alex Huang, Hao F Zhang · 2020 to 2026
$3.5M
Development and Validation of Quantitative Anterior Segment OCT-based Methods to Evaluate Patients with Primary Angle Closure DiseaseK23EY029763 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI XU, BENJAMIN Y. · 2019 to 2023
$1.1M
NCATS NIH HHS UL1 TR001855NEI NIH HHS K23 EY029763NEI NIH HHS P30 EY029220NEI NIH HHS R01 EY030501
6 · The paper itself

Abstract

Purpose: To assess the repeatability and agreement of ocular biometric parameters measured using the Tomey CASIA SS-1000 and Heidelberg ANTERION anterior segment optical coherence tomography (AS-OCT) devices. Methods: Both eyes of subjects 18 years of age or older were scanned three times with the CASIA and ANTERION under standardized dark lighting. One AS-OCT image along the horizontal (temporal-nasal) meridian was analyzed per eye and per scan. Pupillary diameter (PD) was within 15% for all pairwise comparisons. Anterior chamber depth, lens vault, anterior chamber width, angle opening distance, trabecular iris space area, and scleral spur angle (SSA500) were measured using manufacturer-provided image analysis software. Intraclass correlation (ICC), Wilcoxon signed-rank, and Bland-Altman analyses were performed to assess intradevice repeatability and interdevice agreement of measurements. Results: Thirty-two eyes of 21 subjects were analyzed. There was excellent agreement (ICC >0.98) and no significant difference ( Conclusions: Intradevice measurement repeatability is excellent for the CASIA and ANTERION. Interdevice measurement agreement between the two devices exceeds metrics reported by previous comparison studies. Translational Relevance: Modern swept-source AS-OCT devices produce highly repeatable measurements of ocular biometric parameters that are nearly interchangeable across devices.

Indexed as

BiometryLens, CrystallineAdolescentAdultAnterior ChamberHumansIrisReproducibility of ResultsTomography, Optical Coherenceanterior segment OCTocular biometric measurementsprimary angle closure diseaseswept source OCT

Identifiers

PMID32879770
PMCPMC7442878

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.