Evidence map›Paper›PMID 32877984›Full record

ArticleJournal of clinical medicine2020

Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up.

Wojciech Poncyljusz, Kinga Kubiak, Leszek Sagan, Bartosz Limanówka, Katarzyna Kołaczyk

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.4field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Early clinical experience with the ACCEROInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. pCONUS 2 and pCONUS 2-HPC for the treatment of wide-necked intracranial aneurysms: Periprocedural, 6-month, and early 2-year follow-up outcomes.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2021
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Wojciech PoncyljuszDepartment of Diagnostic Imaging and Interventional Radiology, Pomeranian Medical University, 71-252 Szczecin, Poland.ORCID 0000-0002-5173-5635
Kinga KubiakDepartment of Diagnostic Imaging and Interventional Radiology, Pomeranian Medical University, 71-252 Szczecin, Poland.ORCID 0000-0002-7626-5211
Leszek SaganDepartment of Neurosurgery and Pediatric Neurosurgery, Pomeranian Medical University, 71-252 Szczecin, Poland.ORCID 0000-0001-5366-1070
Bartosz LimanówkaDepartment of Neurosurgery and Pediatric Neurosurgery, Pomeranian Medical University, 71-252 Szczecin, Poland.ORCID 0000-0002-7440-0088
Katarzyna KołaczykDepartment of Diagnostic Imaging and Interventional Radiology, Pomeranian Medical University, 71-252 Szczecin, Poland.ORCID 0000-0002-8973-8700
Pomeranian Medical University · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundStent-assisted coiling is an effective method of treating intracranial aneurysms. The aim of the study was to assess the safety and efficacy of the new Accero stent for the treatment of intracranial aneurysms. MATERIALS AND

methodsIt was a retrospective, single-center study. Eighteen unruptured intracranial aneurysms were treated using the stent-assisted coiling method with the Accero stent. Patient demographics, aneurysm characteristics, procedural parameters, grade of occlusion, complications, and clinical results were analyzed. Follow-up magnetic resonance (MR) was performed 6 months after intervention.

resultsSeventeen patients with 18 incidental unruptured aneurysms were electively treated with coiling and the Accero stent. The aneurysms were located on internal carotid artery (ICA), middle cerebral artery (MCA) and basilar artery (BA). All stents were deployed successfully. Immediate complete occlusion rate Raymond-Roy occlusion classification (RROC) class I was achieved in 13 cases and class II in 4 cases. Complications occurred in 2/17 treatments and included guidewire stent perforation with subarachnoid hemorrhage (SAH) and stent deformation. Vascular spasm in the subarachnoid hemorrhage (SAH) patient subsided before discharge. Ninety days after intervention, the modified Rankin Scale (mRS) value was 0. RROC class I was observed in 88.23% of cases in follow-up.

conclusionThe Accero stent provides excellent support for coil mass. It constitutes an efficacious device with good initial occlusion rate for treating wide-necked unruptured intracranial aneurysms.

Indexed as

Accerocerebral aneurysmembolizationendovascular treatmentneuroradiology

Identifiers

PMID32877984
PMCPMC7564441
OpenAlexW3082507300

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.