ArticleSensors (Basel, Switzerland)2020
Microsensor Electrodes for 3D Inline Process Monitoring in Multiphase Microreactors.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
We present an electrochemical microsensor for the monitoring of hydrogen peroxide direct synthesis in a membrane microreactor environment by measuring the hydrogen peroxide and oxygen concentrations. In prior work, for the first time, we performed in situ measurements with electrochemical microsensors in a microreactor setup. However, the sensors used were only able to measure at the bottom of the microchannel. Therefore, only a limited assessment of the gas distribution and concentration change over the reaction channel dimensions was possible because the dissolved gases entered the reactor through a membrane at the top of the channel. In this work, we developed a new fabrication process to allow the sensor wires, with electrodes at the tip, to protrude from the sensor housing into the reactor channel. This enables measurements not only at the channel bottom, but also along the vertical axis within the channel, between the channel wall and membrane. The new sensor design was integrated into a multiphase microreactor and calibrated for oxygen and hydrogen peroxide measurements. The importance of measurements in three dimensions was demonstrated by the detection of strongly increased gas concentrations towards the membrane, in contrast to measurements at the channel bottom. These findings allow a better understanding of the analyte distribution and diffusion processes in the microreactor channel as the basis for process control of the synthesis reaction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.